ACI 318-19 §6.2 / §10.6 / §22.4

Braced column bent in double curvature

Opposite-curvature end effects increase the slenderness threshold to its 40 ceiling.

Edit inputs ↓

Inputs

Editable example

Section
Frame & demand
φPn,max 822.49kip
kℓu/r 34.29 
Limit 40 
Steel ρg 1.76%
AnatomyDiagrammatic scale
Parameter-linked column drawing. Diagrammatic scale. WEAK-AXIS ELEVATIONP–M CONCEPTℓuPMφPn,maxAxial cap shown; curve schematicℓu 16.5 ftr 5.2 inkℓu/r 34.29

Screening

Within screening limits
Axial ceiling utilization83.9%
Tied confinement16.1% below the threshold
  • Concentric axial ceilingPu ≤ φPn,max
    Within limit
  • Gross steel ratio1% ≤ Ast/Ag ≤ 8% per §10.6.1.1
    Within limit
  • Slenderness screenkℓu/r at or below the weak-axis limit
    Within limit

The axial ceiling is one point on a column interaction diagram. Check actual eccentricity and P–M strength, reinforcement detailing and any second-order effects before using the section.

Calculation readout
QuantityValue
Design axial ceiling φPn,max822.49 kip
Weak-axis slenderness kℓu/r34.29
Slenderness threshold40
Gross longitudinal ratio1.76 %
Gross area Ag360 in²
Longitudinal steel area Ast6.32 in²
Weak-axis radius r5.196 in
Nominal concentric strength P₀1,581.71 kip
Nominal ceiling Pn,max1,265.37 kip
Compression factor φ0.65
Longitudinal yield used60 ksi

Original example

Worked solution

Default calculator ↗

Starting inputs

Unsupported length lu
16.5 ft
Effective length factor k
0.9
End-moment ratio (+ single curvature)
-0.8
Factored compression Pu
690 kip

Calculated result

Design axial ceiling φPn,max
822.49 kip
Weak-axis slenderness kℓu/r
34.29
Slenderness threshold
40
Gross longitudinal ratio
1.76 %

Use the field’s curvature sign convention. Compare the uncapped expression with 40 before evaluating kℓu/r.

Preset screening · Tied confinement · Within limits

How the check works

Code basis ↗
  1. Compute Ag and P₀ = 0.85f′c(Ag − Ast) + fy Ast with fy limited to 80 ksi. Limit Pn to 0.80P₀ with φ = 0.65 for ties, or 0.85P₀ with φ = 0.75 for spirals.
  2. Screen 1–8% gross reinforcement. Use r = √(Ig/Ag) about the weak axis, then compare k lu/r with the threshold in §6.2.5.1.
  3. Enter M1/M2 as positive for single curvature and negative for double curvature. This is the reverse of the sign in §6.2.5.1, so the braced expression here is min(40, 34 − 12 M1/M2). The unbraced limit is 22.