ACI 318-19 §6.2 / §10.6 / §22.4

Circular spiral column at 2.5% steel

A 22 in circular section is entered using a gross reinforcement percentage.

Edit inputs ↓

Inputs

Editable example

Section
Frame & demand
φPn,max 1,166.84kip
kℓu/r 22.25 
Limit 31 
Steel ρg 2.5%
AnatomyDiagrammatic scale
Parameter-linked column drawing. Diagrammatic scale. WEAK-AXIS ELEVATIONP–M CONCEPTℓuPMφPn,maxAxial cap shown; curve schematicℓu 12 ftr 5.5 inkℓu/r 22.25

Screening

Within screening limits
Axial ceiling utilization87.4%
Spiral confinement12.6% below the threshold
  • Concentric axial ceilingPu ≤ φPn,max
    Within limit
  • Gross steel ratio1% ≤ Ast/Ag ≤ 8% per §10.6.1.1
    Within limit
  • Slenderness screenkℓu/r at or below the weak-axis limit
    Within limit

The axial ceiling is one point on a column interaction diagram. Check actual eccentricity and P–M strength, reinforcement detailing and any second-order effects before using the section.

Calculation readout
QuantityValue
Design axial ceiling φPn,max1,166.84 kip
Weak-axis slenderness kℓu/r22.25
Slenderness threshold31
Gross longitudinal ratio2.5 %
Gross area Ag380.13 in²
Longitudinal steel area Ast9.503 in²
Weak-axis radius r5.5 in
Nominal concentric strength P₀1,830.34 kip
Nominal ceiling Pn,max1,555.79 kip
Compression factor φ0.75
Longitudinal yield used60 ksi

Original example

Worked solution

Default calculator ↗

Starting inputs

Column section
Circular spiral
Steel input
Gross ratio ρg
Gross steel ratio ρg
2.5 %
Unsupported length lu
12 ft
Effective length factor k
0.85
Factored compression Pu
1,020 kip

Calculated result

Design axial ceiling φPn,max
1,166.84 kip
Weak-axis slenderness kℓu/r
22.25
Slenderness threshold
31
Gross longitudinal ratio
2.5 %

Convert the ratio to Ast from the circular gross area before applying spiral factors.

Preset screening · Spiral confinement · Within limits

How the check works

Code basis ↗
  1. Compute Ag and P₀ = 0.85f′c(Ag − Ast) + fy Ast with fy limited to 80 ksi. Limit Pn to 0.80P₀ with φ = 0.65 for ties, or 0.85P₀ with φ = 0.75 for spirals.
  2. Screen 1–8% gross reinforcement. Use r = √(Ig/Ag) about the weak axis, then compare k lu/r with the threshold in §6.2.5.1.
  3. Enter M1/M2 as positive for single curvature and negative for double curvature. This is the reverse of the sign in §6.2.5.1, so the braced expression here is min(40, 34 − 12 M1/M2). The unbraced limit is 22.