ACI 318-19 §6.2 / §10.6 / §22.4

Grade 100 column axial strength cap

High-strength bars are specified, while the nominal axial calculation limits their design yield stress.

Edit inputs ↓

Inputs

Editable example

Section
Frame & demand
φPn,max 1,266.3kip
kℓu/r 21.59 
Limit 31 
Steel ρg 2.22%
AnatomyDiagrammatic scale
Parameter-linked column drawing. Diagrammatic scale. WEAK-AXIS ELEVATIONP–M CONCEPTℓuPMφPn,maxAxial cap shown; curve schematicℓu 11 ftr 5.2 inkℓu/r 21.59

Screening

Within screening limits
Axial ceiling utilization82.9%
Tied confinement17.1% below the threshold
  • Concentric axial ceilingPu ≤ φPn,max
    Within limit
  • Gross steel ratio1% ≤ Ast/Ag ≤ 8% per §10.6.1.1
    Within limit
  • Slenderness screenkℓu/r at or below the weak-axis limit
    Within limit

The axial ceiling is one point on a column interaction diagram. Check actual eccentricity and P–M strength, reinforcement detailing and any second-order effects before using the section.

Calculation readout
QuantityValue
Design axial ceiling φPn,max1,266.3 kip
Weak-axis slenderness kℓu/r21.59
Slenderness threshold31
Gross longitudinal ratio2.22 %
Gross area Ag360 in²
Longitudinal steel area Ast8 in²
Weak-axis radius r5.196 in
Nominal concentric strength P₀2,435.2 kip
Nominal ceiling Pn,max1,948.16 kip
Compression factor φ0.65
Longitudinal yield used80 ksi

Original example

Worked solution

Default calculator ↗

Starting inputs

Longitudinal steel Ast
8 in²
Concrete strength f′c
6,000 psi
Steel yield strength fy
100 ksi
Factored compression Pu
1,050 kip

Calculated result

Design axial ceiling φPn,max
1,266.3 kip
Weak-axis slenderness kℓu/r
21.59
Slenderness threshold
31
Gross longitudinal ratio
2.22 %

Read the steel yield used in the axial expression. The section uses the 80 ksi cap in §22.4.2.1.

Preset screening · Tied confinement · Within limits

How the check works

Code basis ↗
  1. Compute Ag and P₀ = 0.85f′c(Ag − Ast) + fy Ast with fy limited to 80 ksi. Limit Pn to 0.80P₀ with φ = 0.65 for ties, or 0.85P₀ with φ = 0.75 for spirals.
  2. Screen 1–8% gross reinforcement. Use r = √(Ig/Ag) about the weak axis, then compare k lu/r with the threshold in §6.2.5.1.
  3. Enter M1/M2 as positive for single curvature and negative for double curvature. This is the reverse of the sign in §6.2.5.1, so the braced expression here is min(40, 34 − 12 M1/M2). The unbraced limit is 22.