ACI 318-19 §6.2 / §10.6 / §22.4

Short rectangular tied column

An 18 × 20 in tied section carries factored concentric compression in a braced frame.

Edit inputs ↓

Inputs

Editable example

Section
Frame & demand
φPn,max 822.49kip
kℓu/r 21.59 
Limit 31 
Steel ρg 1.76%
AnatomyDiagrammatic scale
Parameter-linked column drawing. Diagrammatic scale. WEAK-AXIS ELEVATIONP–M CONCEPTℓuPMφPn,maxAxial cap shown; curve schematicℓu 11 ftr 5.2 inkℓu/r 21.59

Screening

Within screening limits
Axial ceiling utilization85.1%
Tied confinement14.9% below the threshold
  • Concentric axial ceilingPu ≤ φPn,max
    Within limit
  • Gross steel ratio1% ≤ Ast/Ag ≤ 8% per §10.6.1.1
    Within limit
  • Slenderness screenkℓu/r at or below the weak-axis limit
    Within limit

The axial ceiling is one point on a column interaction diagram. Check actual eccentricity and P–M strength, reinforcement detailing and any second-order effects before using the section.

Calculation readout
QuantityValue
Design axial ceiling φPn,max822.49 kip
Weak-axis slenderness kℓu/r21.59
Slenderness threshold31
Gross longitudinal ratio1.76 %
Gross area Ag360 in²
Longitudinal steel area Ast6.32 in²
Weak-axis radius r5.196 in
Nominal concentric strength P₀1,581.71 kip
Nominal ceiling Pn,max1,265.37 kip
Compression factor φ0.65
Longitudinal yield used60 ksi

Original example

Worked solution

Default calculator ↗

Starting inputs

Column section
Rectangular tied
Steel input
Total area Ast
Concrete strength f′c
4,000 psi
Steel yield strength fy
60 ksi

Calculated result

Design axial ceiling φPn,max
822.49 kip
Weak-axis slenderness kℓu/r
21.59
Slenderness threshold
31
Gross longitudinal ratio
1.76 %

Use the lower of the principal radii of gyration. Compare the axial demand with the tied-column ceiling and then screen slenderness.

Preset screening · Tied confinement · Within limits

How the check works

Code basis ↗
  1. Compute Ag and P₀ = 0.85f′c(Ag − Ast) + fy Ast with fy limited to 80 ksi. Limit Pn to 0.80P₀ with φ = 0.65 for ties, or 0.85P₀ with φ = 0.75 for spirals.
  2. Screen 1–8% gross reinforcement. Use r = √(Ig/Ag) about the weak axis, then compare k lu/r with the threshold in §6.2.5.1.
  3. Enter M1/M2 as positive for single curvature and negative for double curvature. This is the reverse of the sign in §6.2.5.1, so the braced expression here is min(40, 34 − 12 M1/M2). The unbraced limit is 22.