ACI 318-19 §6.2 / §10.6 / §22.4

Slender rectangular column in a sway frame

A narrow weak axis and long unsupported length exceed the unbraced screening limit.

Edit inputs ↓

Inputs

Editable example

Section
Frame & demand
φPn,max 695.19kip
kℓu/r 66.51 
Limit 22 
Steel ρg 2.19%
AnatomyDiagrammatic scale
Parameter-linked column drawing. Diagrammatic scale. WEAK-AXIS ELEVATIONP–M CONCEPTℓuPMφPn,maxAxial cap shown; curve schematicℓu 16 ftr 3.46 inkℓu/r 66.51

Screening

Further analysis required
Axial ceiling utilization50.3%
Tied confinement49.7% below the threshold
  • Concentric axial ceilingPu ≤ φPn,max
    Within limit
  • Gross steel ratio1% ≤ Ast/Ag ≤ 8% per §10.6.1.1
    Within limit
  • Slenderness screenSecond-order analysis or moment magnification required
    Review

The axial ceiling is one point on a column interaction diagram. Check actual eccentricity and P–M strength, reinforcement detailing and any second-order effects before using the section.

Calculation readout
QuantityValue
Design axial ceiling φPn,max695.19 kip
Weak-axis slenderness kℓu/r66.51
Slenderness threshold22
Gross longitudinal ratio2.19 %
Gross area Ag288 in²
Longitudinal steel area Ast6.32 in²
Weak-axis radius r3.464 in
Nominal concentric strength P₀1,336.91 kip
Nominal ceiling Pn,max1,069.53 kip
Compression factor φ0.65
Longitudinal yield used60 ksi

Original example

Worked solution

Default calculator ↗

Starting inputs

Section width b
12 in
Section depth h
24 in
Unsupported length lu
16 ft
Effective length factor k
1.2
Sidesway restraint
Unbraced
Factored compression Pu
350 kip

Calculated result

Design axial ceiling φPn,max
695.19 kip
Weak-axis slenderness kℓu/r
66.51
Slenderness threshold
22
Gross longitudinal ratio
2.19 %

The axial ceiling is still reported. The slenderness result calls for a second-order evaluation.

Preset screening · Tied confinement · Further analysis required

How the check works

Code basis ↗
  1. Compute Ag and P₀ = 0.85f′c(Ag − Ast) + fy Ast with fy limited to 80 ksi. Limit Pn to 0.80P₀ with φ = 0.65 for ties, or 0.85P₀ with φ = 0.75 for spirals.
  2. Screen 1–8% gross reinforcement. Use r = √(Ig/Ag) about the weak axis, then compare k lu/r with the threshold in §6.2.5.1.
  3. Enter M1/M2 as positive for single curvature and negative for double curvature. This is the reverse of the sign in §6.2.5.1, so the braced expression here is min(40, 34 − 12 M1/M2). The unbraced limit is 22.