Slenderness screenSecond-order analysis or moment magnification required
Review
The axial ceiling is one point on a column interaction diagram. Check actual eccentricity and P–M strength, reinforcement detailing and any second-order effects before using the section.
Compute Ag and P₀ = 0.85f′c(Ag − Ast) + fy Ast with fy limited to 80 ksi. Limit Pn to 0.80P₀ with φ = 0.65 for ties, or 0.85P₀ with φ = 0.75 for spirals.
Screen 1–8% gross reinforcement. Use r = √(Ig/Ag) about the weak axis, then compare k lu/r with the threshold in §6.2.5.1.
Enter M1/M2 as positive for single curvature and negative for double curvature. This is the reverse of the sign in §6.2.5.1, so the braced expression here is min(40, 34 − 12 M1/M2). The unbraced limit is 22.
The axial ceiling is one point on a column interaction diagram. Check actual eccentricity and P–M strength, reinforcement detailing and any second-order effects before using the section.