869.525 MHz EU Meshtastic Long Fast Solar Node

Estimate EU Meshtastic Long Fast airtime at 869.525 MHz, screen the 10% sub-band and size a LiFePO₄ supply for winter.

Jump to results ↓

Inputs

Packet & modem
Count all bytes handed to the radio, including mesh or application overhead.
Region & traffic
Include local retransmissions, relays, beacons and acknowledgments.
Link budget
LiFePO₄ & solar power

Results

Preset estimate
Packet time on air 477.184ms

Within airtime budget

Hourly TX duty
1.5906 %
Usable battery
6.912 Wh
No-sun runtime
2.86 days
LoRa packet time and daily power budgetPACKET TIMING477.184 msPreamble 165.888 msPayload 311.296 msDAILY ENERGYWh / dayLoad2.414 WhSolar harvest0.65 WhTXRXIdle
Packet duration by segment and battery-side energy use versus solar harvest.

Modem timing

Symbol duration
8.192 ms
Preamble time
165.888 ms
Payload time
311.296 ms
Payload symbols
38
Low data rate optimization
Off

Regional airtime screen

Local TX time
57.262 s / h
Hourly TX duty
1.5906 %
Nominal occupied channel
Inside selected band
Airtime ceiling
360 s / h
Whole packets at ceiling
754 / h

Path & sensitivity

Receiver sensitivity
-131.52 dBm
Friis path loss
105.21 dB
Friis received level
-88.91 dBm
Friis available margin
42.61 dB
Friis margin after target
27.61 dB
Friis range at target margin
120.05 km

Battery & solar

Daily consumption
2.414 Wh
Daily solar harvest
0.65 Wh
Daily net energy
-1.764 Wh
Usable stored energy
6.912 Wh
No-sun days
2.86 days
Solar-assisted runtime
3.92 days
Break-even panel rating
3.71 W
Driver-neutral C and Python settings

C99

/* Semtech SX1262 PHY values. Map them to your radio driver and match the peer. */
#include <stdbool.h>
#include <stdint.h>

static const struct {
    uint32_t frequency_hz, bandwidth_hz;
    uint16_t preamble_symbols;
    uint8_t spreading_factor, coding_rate_denominator, payload_bytes;
    bool implicit_header, crc_enabled, low_data_rate_optimize;
} lora_config = {
    .frequency_hz = 869525000,
    .bandwidth_hz = 250000,
    .preamble_symbols = 16,
    .spreading_factor = 11,
    .coding_rate_denominator = 5,
    .payload_bytes = 32,
    .implicit_header = false,
    .crc_enabled = true,
    .low_data_rate_optimize = false,
};

Python

# Semtech SX1262 PHY values. Map them to your radio driver and match the peer.
lora_config = {
    "frequency_hz": 869525000,
    "bandwidth_hz": 250000,
    "preamble_symbols": 16,
    "spreading_factor": 11,
    "coding_rate_denominator": 5,
    "payload_bytes": 32,
    "implicit_header": False,
    "crc_enabled": True,
    "low_data_rate_optimize": False,
}

Worked example

A 250 kHz nominal channel centered on 869.525 MHz has nominal edges at 869.4 and 869.65 MHz. This is the CEPT h1.7 planning profile used here. Compare the band and duty screen with the applicable national limits and your equipment configuration.

With a 1 W panel and one peak sun hour, this 3 Ah node has a daily energy deficit in the preset. Check the solar-runtime readout against no-sun autonomy. A better panel location or lower measured receive load can change the sizing before you increase battery capacity.

Packet time on air
477.184 ms
Hourly TX duty
1.5906 %
Usable battery
6.912 Wh
No-sun runtime
2.86 days

Formulas & assumptions

  • Tsymbol = 2^SF / BW. BW is in Hz for seconds per symbol.
  • Npayload = 8 + CRden × max(ceil((8PL − 4SF + 28 + 16CRC − 20IH) / (4(SF − 2DE))), 0). PL is the radio payload bytes, CRC is 1 when enabled, IH is 1 for implicit header and DE is 1 for LDRO.
  • Tpacket = (Npreamble + 4.25 + Npayload) × Tsymbol. SX1262 and SX1276 use the same symbol count for SF7–SF12 with identical settings.
  • Duty = local transmissions per hour × Tpacket / 3,600. In the US FHSS screen, occupancy is Tpacket times the busiest-channel packet count in the listed window.
  • Load (Wh/day) = V × Σ(state current in A × state hours). Harvest = panel W × peak sun hours × yield. No-sun runtime = usable Wh / daily load.
  • Friis loss = 20 log₁₀(4πd/λ). Hata uses an environment-specific intercept plus (44.9 − 6.55 log₁₀(hbase)) log₁₀(dkm).

Use the actual radio payload, header and CRC setting. Confirm the radio’s LDRO register when matching captures. Host-to-radio delay and channel access time are outside time on air.

EU profiles screen nominal occupied band edges and the chosen duty budget. The US FHSS option checks the selected dwell and channel-count criteria only. Equipment approval, actual spectral occupancy, power and local rules need their own checks.

Hata is available for 150–1,500 MHz, a 30–200 m base, a 1–10 m mobile and 1–20 km. Friis range is an unobstructed algebraic estimate. Receiver sensitivity depends on the hardware and packet error criterion.

Enter currents measured at the same battery-side voltage, including MCU and regulator load. Use winter peak sun hours and check the pack’s permitted charging temperature.

References

Questions & answers

Why does 869.525 MHz have a different duty-cycle screen?

Its nominal 250 kHz channel fits the 869.4–869.65 MHz sub-band. This preset uses the 10% CEPT h1.7 profile.

What should I enter for a shaded EU Meshtastic site in December?

Use peak sun hours and an efficiency estimate representative of the installed winter orientation and shading. Test a separate zero-sun scenario for reserve.