Grounded coplanar waveguide calculator

Design finite-ground CPW or grounded CPWG with elliptic-integral impedance, target width or gap, and via-fence pitch.

Readout

Ghione–Naldi / AGM
Z₀
54.549Ω
EFFECTIVE DK
2.577
GUIDED λ
15.563mm
MAX VIA PITCH
0.77814mm
Via pitch passThe actual pitch meets the λg/20 screen.
Coplanar waveguide live schematicGround–signal–groundTOP VIEWGNDSIGGNDW 0.34 mmG 0.16 mmConductor-backed CPWGCROSS-SECTIONPitch 0.65 mmVia limit 0.77814 mmCLOSER VIASλg / 20WIDER SPACING

Ground & synthesis results

QuantityValue
Target offset+9.0978%
Target width at fixed gap0.4082 mm / 16.071 mil
Target gap at fixed width0.10627 mm / 4.1838 mil
Maximum stitching pitch0.77814 mm / 30.635 mil
Dielectric filling factor0.59284
Upper / lower AGM ratios0.87583 / 1.2753

How to read this result

Finite top ground enters the upper half-plane modulus. Unbacked CPW uses the finite dielectric-height sinh map. Backed CPWG uses the tanh map for the ideal lower conductor, with a first-order effective-slot correction for copper thickness.

The AGM evaluates the elliptic integral ratios to floating-point precision. The quasi-static partial-capacitance model still assumes an ideal continuous backing for CPWG. Via pitch is a λg/20 layout check. Verify slotline, parallel-plate modes and launch geometry in EM.

Methods & references

Coplanar waveguide examples

All 50 examples