Passive LC filter design calculator

Synthesize Butterworth and Chebyshev low-pass, high-pass and band-pass ladders with exact ideal S-parameters.

Readout

Prototype g values / ABCD
PROBE IL
30.107dB
PROBE RL
0.0042391dB
EDGE IL
3.0103dB
ORDER N
5
Ladder synthesizedS-parameters are calculated from the ideal two-port matrix.
Passive LC filter live schematicSynthesized LC ladderLP · PI12345R₀ sourceR₀ loadScattering response · dBS₂₁ / S₁₁-60-3000.421.23.42|S₂₁||S₁₁|Frequency (GHz)BELOW f₀REFERENCE f₀ABOVE f₀

Probe & reference frequencies

Frequency pointGHzILRL
Cutoff1.23.0103 dB3.0103 dB
Half-reference0.60.0042391 dB30.107 dB
Double-reference2.430.107 dB0.0042391 dB
User probe2.430.107 dB0.0042391 dB

Ladder component values

LeggₖArrangementValues
10.618034ShuntC 1.6394 pF
21.618034SeriesL 10.73 nH
32ShuntC 5.3052 pF
41.618034SeriesL 10.73 nH
50.618034ShuntC 1.6394 pF

Prototype terminations

QuantityValue
g₀ / gₙ₊₁1 / 1
Required ladder load50 Ω
Physical port R₀50 Ω
Ideal turns ratio (ladder : load)1:1

How to read this result

Each prototype leg is mapped into a series impedance or shunt admittance. In band-pass mode those become resonant LC pairs and the specified center is the geometric mean of the two passband edges. Insertion and return loss are positive dB magnitudes.

Responses use ideal lumped components. An even-order Chebyshev prototype needs an unequal ladder termination. The ideal transformer option preserves its ripple with equal external ports. LC-only mode shows the actual equal-port response.

Methods & references

Passive LC filter examples

All 50 examples