FM receiver high-pass ladder

A series-first high-pass rejects the lower-frequency signals reaching an FM lab front end.

Readout

Prototype g values / ABCD
PROBE IL
18.129dB
PROBE RL
0.067334dB
EDGE IL
3.0103dB
ORDER N
3
Ladder synthesizedS-parameters are calculated from the ideal two-port matrix.
Passive LC filter live schematicSynthesized LC ladderHP · T123R₀ sourceR₀ loadScattering response · dBS₂₁ / S₁₁-60-3000.02450.06990.2|S₂₁||S₁₁|Frequency (GHz)BELOW f₀REFERENCE f₀ABOVE f₀

Probe & reference frequencies

Frequency pointGHzILRL
Cutoff0.073.0103 dB3.0103 dB
Half-reference0.03518.129 dB0.067334 dB
Double-reference0.140.067334 dB18.129 dB
User probe0.03518.129 dB0.067334 dB

Ladder component values

LeggₖArrangementValues
11SeriesC 45.473 pF
22ShuntL 56.841 nH
31SeriesC 45.473 pF

Prototype terminations

QuantityValue
g₀ / gₙ₊₁1 / 1
Required ladder load50 Ω
Physical port R₀50 Ω
Ideal turns ratio (ladder : load)1:1

How to read this result

Each prototype leg is mapped into a series impedance or shunt admittance. In band-pass mode those become resonant LC pairs and the specified center is the geometric mean of the two passband edges. Insertion and return loss are positive dB magnitudes.

Responses use ideal lumped components. An even-order Chebyshev prototype needs an unequal ladder termination. The ideal transformer option preserves its ripple with equal external ports. LC-only mode shows the actual equal-port response.