A five-pole 50 Ω Butterworth ladder suppresses a transmitter’s second harmonic.
915 MHz telemetry band-pass
A narrowband resonator ladder passes the regional ISM allocation around 915 MHz.
Readout
Prototype g values / ABCDProbe & reference frequencies
| Frequency point | GHz | IL | RL |
|---|---|---|---|
| Center | 0.915 | 0 dB | ∞ dB |
| Lower band edge | 0.90209 | 0.5 dB | 9.6357 dB |
| Upper band edge | 0.92809 | 0.5 dB | 9.6357 dB |
| Half-reference | 0.45105 | 106.87 dB | 8.9328e-11 dB |
| Double-reference | 1.8562 | 106.87 dB | 8.9328e-11 dB |
| User probe | 0.96 | 34.056 dB | 0.0017073 dB |
Ladder component values
| Leg | gₖ | Arrangement | Values |
|---|---|---|---|
| 1 | 1.59628 | Series | L 488.57 nH · C 0.061926 pF |
| 2 | 1.096692 | Shunt | L 0.22534 nH · C 134.26 pF |
| 3 | 1.59628 | Series | L 488.57 nH · C 0.061926 pF |
Prototype terminations
| Quantity | Value |
|---|---|
| g₀ / gₙ₊₁ | 1 / 1 |
| Required ladder load | 50 Ω |
| Physical port R₀ | 50 Ω |
| Ideal turns ratio (ladder : load) | 1:1 |
How to read this result
Each prototype leg is mapped into a series impedance or shunt admittance. In band-pass mode those become resonant LC pairs and the specified center is the geometric mean of the two passband edges. Insertion and return loss are positive dB magnitudes.
Responses use ideal lumped components. An even-order Chebyshev prototype needs an unequal ladder termination. The ideal transformer option preserves its ripple with equal external ports. LC-only mode shows the actual equal-port response.
Passive LC filter examples
All 50 examplesA series-first high-pass rejects the lower-frequency signals reaching an FM lab front end.
A narrowband resonator ladder passes the regional ISM allocation around 915 MHz.
A four-pole low-pass prototype is synthesized for 0.1 dB ripple and equal VNA ports.
A five-pole LC starting point rejects image energy outside the receiver passband.
A higher-order filter limits an intermediate frequency on a media receiver input.