PCIe Gen5 via-stub screen

A 32 Gb/s NRZ lane runs over VLP copper with a long remaining plated-through stub.

Readout

Hammerstad–Bekkadal / λ/4
SKIN DEPTH
0.52245µm
ROUGHNESS K
1.684×
CHANNEL LOSS
3.2845dB
VIA NOTCH
13.384GHz
Back-Drill RequiredThe ideal first stub notch is at or below lane Nyquist.
Skin loss & via stub live schematicPlated-through via cross-sectionSTUBSignal exitPTH barrelL-stub 2.8 mmDk 4Channel transmission · dBτ / λ-12-603.759.1622.4Line lossWith ideal stubNyquist 16 GHzNotch 13.38 GHzFrequency (GHz)LOW f-notchNYQUISTHIGH f-notch

Loss budget & stub screen

QuantityValue
Conductor attenuation0.2222 dB/cm / 0.56438 dB/in
Dielectric attenuation0.10626 dB/cm / 0.26989 dB/in
Total line attenuation0.32845 dB/cm / 0.83427 dB/in
Ideal first stub notch13.384 GHz
Lane symbol rate32 GBd
Lane Nyquist16 GHz
Notch / Nyquist0.83647 ×
Remaining stub length2.8 mm / 110.24 mil

How to read this result

Nyquist uses symbol rate, so a PAM4 lane has half the baud rate of NRZ at a given bit rate. At or below Nyquist the quarter-wave screening flag reads Back-Drill Required. Rise-time spectral energy can still matter beyond Nyquist.

Line loss uses smooth copper plus a Hammerstad–Bekkadal RMS roughness multiplier. The plotted via is an ideal shunt open stub. Real notch depth and location depend on pads, antipads, nearby return vias, connector launch and dielectric variation.

Methods & references

Skin loss & via stub examples

All 50 examples