Mixed-pitch main roof, porch and dormer takeoff
A renovation combines a 1,000 ft² main roof at 6:12, a 400 ft² porch at 3:12 and a 225 ft² dormer at 8:12.
Worked calculation
Convert each projected area using its own pitch factor. Together the planes cover about 1,801 ft² of deck. Check the low-slope assembly for the porch separately.
Change the inputs to test your own measurements. Reset restores this example.
Results
LiveCorrect the highlighted inputs to update your results.
- Field shingle bundles
- Order area in roofing squares
- Horizontal area
- Measured sloped area
- Field cut allowance
- Field order area
- Starter packages
- Ridge and hip cap bundles
- Underlayment rolls
- Eave ice-barrier area
- Ice-barrier rolls
- Field shingle nails
- Field nail boxes
- From 2:12 to below 4:12, verify the special underlayment application and product requirements for asphalt shingles.
- The underlayment takeoff currently includes one layer. Review the required low-slope installation and adjust coverage.
Worksheet inputs US customary
- Area input
- Up to four roof planes
- Plane 1 projected area
- 1,000 ft²
- Plane 1 pitch
- 6:12
- Plane 2 projected area
- 400 ft²
- Plane 2 pitch
- 3:12
- Plane 3 projected area
- 225 ft²
- Plane 3 pitch
- 8:12
- Plane 4 projected area
- 0 ft²
- Roof shape and cut allowance
- Cut-up roof · 18%
- Shingle package basis
- Architectural · 3 bundles/square
- Eaves and rakes for starter
- 184 ft
- Ridges and hips for cap
- 75 ft
- Eaves receiving ice barrier
- 100 ft
- Ice-barrier width along slope
- 3 ft
- Full underlayment layers
- One layer
- Actual field coverage per bundle
- 0 ft²
- Starter coverage per package
- 120 ft
- Cap coverage per package
- 25 ft
- Net underlayment coverage per roll
- 900 ft²
- Net ice-barrier coverage per roll
- 180 ft²
- Shingles per 100 ft² (one roofing square)
- 64
- Nails per field shingle
- 4
- Nails per box
- 7,200
Apply this example to your roof
Confirm the shingle label, regional code, wind fastening pattern, underlayment courses and ice-barrier extent. Membrane, starter, cap and underlayment are separate estimates. Add valleys, penetrations, overlaps and accessory fasteners as applicable.
Frequently asked questions
Can the dormer and porch share the main roof pitch factor?
Use each area’s own factor. Applying the 6:12 factor to every plane overstates the porch and understates the dormer.
How do I represent a roof with a fifth measured plane?
Combine projected planes that share a pitch or run a separate takeoff for the extra section. Keep shared edge items in one order.