RoomAcousticLab · Calculation record
Helmholtz resonator example
Deep cavity for a 63 Hz mode
A deeper airspace shifts the estimated resonance downward. Use the target depth readout to see how much further the cavity would need to move.
Inputs
- Resonance
- 62.3Hz
- Quarter wave
- 238.3Hz
- Target error
- -0.7Hz
- Open area
- 1.25%
Acoustic absorber cavity section
Illustrative scaleResonance within the tuning window
PassThe estimated peak is within 5% of the target and the cavity, neck and pitch meet the compactness screen.
Within 5%5–15% / reviewOver 15%
Input snapshot
- Panel type
- Perforated panel
- Panel thickness
- 21 mm
- Hole diameter
- 8 mm
- Open area
- 1.25%
- Hole end correction
- Linear Fok
- Cavity depth
- 360 mm
- Target frequency
- 63 Hz
- Air temperature
- 20 °C
Calculation breakdown
- End correction
- 5.736 mm
- Geometry correction factor
- 0.8435
- Effective neck length
- 26.736 mm
- Opening pitch
- 63.413 mm
- Depth for exact modelled target
- 351.49 mm
- Absolute frequency error
- 1.2%
- Compact wavelength screen
- Within λ/8
The tuning estimate assumes a rigid panel, rigid backing and small-signal motion. Surface resistance, porous backing, construction tolerances and leakage affect measured absorption and bandwidth.