Helmholtz resonator example

Deep cavity for a 63 Hz mode

A deeper airspace shifts the estimated resonance downward. Use the target depth readout to see how much further the cavity would need to move.

Inputs

Panel & cavity
Frequency & air
Resonance
62.3Hz
Quarter wave
238.3Hz
Target error
-0.7Hz
Open area
1.25%

Acoustic absorber cavity section

Illustrative scale
Cross-section of acoustic resonatorA panel opening feeds a rigidly backed air cavity. Geometry labels show the hole or slot dimension and cavity depth.PERFORATED FACERIGID BACKINGØ 8 mmDepth 360 mm
OpeningCavityRigid backing

Resonance within the tuning window

Pass

The estimated peak is within 5% of the target and the cavity, neck and pitch meet the compactness screen.

Within 5%5–15% / reviewOver 15%

Calculation breakdown

End correction
5.736 mm
Geometry correction factor
0.8435
Effective neck length
26.736 mm
Opening pitch
63.413 mm
Depth for exact modelled target
351.49 mm
Absolute frequency error
1.2%
Compact wavelength screen
Within λ/8