Worked example

HP100 Breathing Rate from an 80 ft Wreck Segment

An HP100 drops from 3,300 to 1,800 psi during a 28-minute timed stretch. Average depth over that exact interval is 80 ft.

Inputs

psi
psi
ft
min
ft
min

Results

Live calculation
Respiratory minute volume
0.45ft³/min
12.87 L/min
Surface-equivalent gas per minute.
Surface air consumption
15.64psi/min
Pressure rate for the selected cylinder.
Measured gas used
43.6ft³
Next dive gas estimate
44.5ft³
Based on the same breathing rate.
Next dive pressure draw
1,533.2psi
On this cylinder, before reserve.
Pressure use over timeMeasured 1,500 psi and projected 1,533.2 psi of pressure draw on HP100. Pressure use over timePRESSURE USED · psi0040010800201,200301,60040TIME · minTeal measured · gold projected

Work through this example

A pressure drop alone cannot be compared across tanks. Use the HP100 rated gas and service pressure to normalize the observed draw to free gas.

Try it. Change only the projected average depth to 80 ft and compare projected pressure with the observed pressure drop.

How the calculation works

Normalize to the surface

SAC = (starting pressure − ending pressure) ÷ average ambient ATA ÷ elapsed minutes. Temperature and workload can shift pressure readings and breathing rates.

Convert pressure to free gas

RMV = SAC × rated free gas ÷ rated gauge pressure. Multiply RMV by next-dive ambient ATA and time to project free gas. Presets use nominal linear pressure-to-volume factors. The 12 L and 15 L tanks use ideal 1 ATA free gas at 232 bar.

References

Questions & answers

Which HP100 pressure matters when converting SAC to RMV?

Use the rated pressure for the conversion. The start and end gauge pressures supply the observed pressure change.

Why can a wreck-swim RMV differ from a relaxed reef RMV?

Finning, current, equipment load and tasks influence breathing. Use a representative sample for the next planned workload.