Worked example
Trimix 21/20 at 195 ft Above the Density Ceiling
This technical comparison uses a relatively small helium fraction to demonstrate a mix beyond the 6.2 g/L density reference at 195 ft.
Inputs
Results
Live calculationFix the highlighted inputs to view the results and diagram.
- PPO₂ exceeds the 1.4 ATA working reference. Treat 1.6 ATA as a contingency reference only.
- Gas density exceeds 6.2 g/L, the upper reference for increased breathing effort and CO₂ retention.
- Inspired gas density
- 7.42g/L
- Dry ideal gas at depth, referenced to 0 °C.
- Equivalent narcotic depth
- 137.3ft
- Oxygen partial pressure
- 1.451ATA
- Nitrogen partial pressure
- 4.076ATA
- Nitrogen remainder
- 59%
Work through this example
A chart marker above both reference lines exposes the density concern. The oxygen pressure can also exceed its working reference independently.
Try it. Increase helium by ten percentage points while holding oxygen and depth fixed.
How the calculation works
Apply Dalton’s law
Nitrogen is 100% minus the oxygen and helium percentages. Each partial pressure is its fraction times ambient ATA. The model flags mixes below 16% O₂ at the surface.
Compare density and narcosis
Mix the 1 ATA dry-gas densities of oxygen (1.429 g/L), nitrogen (1.251 g/L) and helium (0.1785 g/L), then multiply by ambient ATA. END matches the modeled narcotic fraction in air, treating both O₂ and N₂ or only N₂ as narcotic. The model floors negative END at zero.
References
More worked examples
Questions & answers
Can trimix 21/20 still exceed the gas-density ceiling?
Yes. A modest helium fraction may leave too much density at high ambient pressure. The model evaluates the full blend.
Which result shows the nitrogen replaced by extra helium in 21/20?
Nitrogen remainder drops one percentage point for every point of extra helium at fixed oxygen. PPN₂ drops with it.