Worked example

Trimix 21/20 at 195 ft Above the Density Ceiling

This technical comparison uses a relatively small helium fraction to demonstrate a mix beyond the 6.2 g/L density reference at 195 ft.

Inputs

%
%
ft

Results

Live calculation
  • PPO₂ exceeds the 1.4 ATA working reference. Treat 1.6 ATA as a contingency reference only.
  • Gas density exceeds 6.2 g/L, the upper reference for increased breathing effort and CO₂ retention.
Inspired gas density
7.42g/L
Dry ideal gas at depth, referenced to 0 °C.
Equivalent narcotic depth
137.3ft
Oxygen partial pressure
1.451ATA
Nitrogen partial pressure
4.076ATA
Nitrogen remainder
59%
Gas composition and density21% oxygen, 20% helium, 59% nitrogen and 7.42 grams per liter. Gas composition and densityO₂ 21%He 20%N₂ 59%INSPIRED DENSITYDepth 195 ft7.42 g/L5.2 preferred6.2 upper ref.

Work through this example

A chart marker above both reference lines exposes the density concern. The oxygen pressure can also exceed its working reference independently.

Try it. Increase helium by ten percentage points while holding oxygen and depth fixed.

How the calculation works

Apply Dalton’s law

Nitrogen is 100% minus the oxygen and helium percentages. Each partial pressure is its fraction times ambient ATA. The model flags mixes below 16% O₂ at the surface.

Compare density and narcosis

Mix the 1 ATA dry-gas densities of oxygen (1.429 g/L), nitrogen (1.251 g/L) and helium (0.1785 g/L), then multiply by ambient ATA. END matches the modeled narcotic fraction in air, treating both O₂ and N₂ or only N₂ as narcotic. The model floors negative END at zero.

References

Questions & answers

Can trimix 21/20 still exceed the gas-density ceiling?

Yes. A modest helium fraction may leave too much density at high ambient pressure. The model evaluates the full blend.

Which result shows the nitrogen replaced by extra helium in 21/20?

Nitrogen remainder drops one percentage point for every point of extra helium at fixed oxygen. PPN₂ drops with it.