Minimum VRAM for a 405B FP8 model

A large inference deployment tests a 405B FP8 model with eight 8K sequences. The 126-layer configuration uses 141 GB devices with 88% available to the runtime.

Jump to results

Inputs

Model and context
B
%
GPU and runtime

Enter bandwidth independently of the memory preset. Capacity and bandwidth specifications use decimal GB.

GB/s
%
%

Results

Runs in your browser
Required memory
504.646GB
Minimum GPU count
5GPUs Aggregate memory lower bound
Decode bandwidth ceiling
437.534tok/s Ideal aggregate across the batch

Compare measured decode speed with this bandwidth ceiling. Verify the model fits each rank individually.

GPU memory footprint
GPU memory footprint504.646 GB required on 5 devices. 33.823 GB of KV cache.Used VRAM504.646 GBWeightsKV cacheWorkspaceFree5 × 124.08 GB usable8,192 tokens / sequence
Detailed results
Model weights405 GB
Active KV cache33.823 GB
Activation and scratch reserve65.823 GB
Usable memory per GPU124.08 GB
Usable memory across GPUs620.4 GB
KV per cached token516.096 kB
Ceiling per sequence54.692 tok/s

What to try

The computed memory lower bound is five cards. Compare the actual sharding degrees supported by the runtime before selecting a topology or assuming five ranks are feasible.

How the estimate works

KV bytes = 2 × layers × hidden width × KV-head ratio × bytes × tokens × sequences

The model assumes dense decoder-only attention. FP16 uses two bytes per parameter, FP8 and INT8 use one, and Q4_K_M uses a rough 0.60 bytes to include mixed precision and quantization metadata. Use the actual model file size to check this assumption.

Keys and values grow with the live context and batch. GQA reduces the cached width by the ratio of KV heads to query heads. Workspace is an adjustable percentage of weights plus KV, with a separate allowance for unavailable GPU memory.

The GPU count is a memory lower bound. The decode ceiling assumes perfect sharding and one sweep of weights and active KV per batch step at full bandwidth. Kernel overhead, compute, prefill, cache sharing, allocator fragmentation, and interconnect can lower measured output.

Frequently asked questions

Why might a 405B deployment choose eight GPUs when the memory estimate says five?

Tensor dimensions, NVLink topology and supported parallel sizes can require different rank counts. The aggregate memory lower bound does not enforce those placement rules.

Is 405B FP8 weight memory the same after loading every checkpoint?

It depends on how the runtime casts weights and retains quantization scales or auxiliary buffers. Check allocation telemetry after the model has loaded.