Memory-bound analytics workers on Kubernetes
Sixty-four analysis pods keep segments resident and request 9 GiB each. A 16-vCPU worker pool reserves a combined 16% for the system and agents.
Jump to resultsInputs
Results
Runs in your browser- Workers needed
- 14nodes 13 packed · 1 spare
- Pods per worker
- 5pods Memory limiting
- Node cost
- $7,256.20/ month
Combined pod limits exceed packed capacity. Test what happens when many pods burst together.
| Allocatable CPU per worker | 13.44 vCPU |
|---|---|
| Allocatable memory per worker | 53.76 GiB |
| Slots from CPU requests | 53 pods |
| Slots from memory requests | 5 pods |
| Packed worker CPU requested | 9.158 % |
| Packed worker memory requested | 82.418 % |
| Unused packed CPU | 158.72 vCPU |
| Unused packed memory | 122.88 GiB |
| CPU limits / packed allocatable | 36.63 % |
| Memory limits / packed allocatable | 109.89 % |
What to try
Memory sets the limit at five pods per worker, leaving CPU available. Compare a memory-optimized shape by checking its actual allocatable ratio outside the balanced presets.
How the estimate works
Pods per node = min(CPU slots, memory slots, pod cap)
Node allocatable is the preset capacity minus the combined kubelet, OS, and DaemonSet shares. The workload uses identical pods, so rounding each resource’s slot count down gives an exact fit under these assumptions.
Limits estimate burst demand. Kubernetes uses requests to place pods. The chart shows one fully packed worker, any partially packed worker, and the optional spare.
Unused capacity on the packed workers measures the cost of resource imbalance and partially filled nodes. N+1 covers one worker failure under this model. Model zones, affinities, storage, and topology spread separately. Cost uses 730 hours per month.
Frequently asked questions
Why is cluster-wide free memory misleading for analytics pods?
A pod’s entire 9 GiB request must fit on one worker. Several workers with 3 GiB free cannot combine their remaining capacity to admit it.
Should I reduce analytics memory requests to fit a sixth pod?
Measure working sets during peak partitions and failure replay. A lower request improves placement but can raise eviction risk when nodes are under memory pressure.