Large fixture slide clearance
ISO 286-1 / 286-2 / SI units
- Min clearance
- 76 µm
- Max clearance
- 256 µm
- Hole tolerance
- 110 µm
- Shaft tolerance
- 70 µm
Inputs
- Basic diameter
- 630 mm
- Preferred fit
- H8/f7
- Hole letter
- H
- Hole grade
- IT8
- Shaft letter
- f
- Shaft grade
- IT7
Limit dimensions · H8/f7
| Feature | Lower deviation | Upper deviation | Minimum | Maximum | IT width |
|---|---|---|---|---|---|
| Hole H8 | 0 µm | 110 µm | 630 mm | 630.11 mm | 110 µm |
| Shaft f7 | −146 µm | −76 µm | 629.854 mm | 629.924 mm | 70 µm |
Fit checks
| Check | Result |
|---|---|
| Minimum interference | 0 µm |
| Maximum interference | 0 µm |
| IT size step | 500 mm < D ≤ 630 mm |
| Reference unit I | 4.344994 µm |
Negative signed clearance is interference. Limits for H8/f7 use the upper-inclusive ISO size step. A line-to-line endpoint belongs to the corresponding clearance or interference class. ISO leaves some grades and size combinations blank. Calculated fit assumes perfect geometry and ambient design dimensions.