Calculation methodology
How the workbench turns measured values and drawing limits into design and inspection results.
Enter drawing values and choose a model
Start with an editable case or enter your own values. The unit switch changes presentation while retaining the stored SI values. The drawing limits and the physical meaning of each input determine which model to use.
Use the JSON export for machine-readable values, CSV for the current readout, SVG or PNG for the schematic and A4 for the inspection summary. Share inputs generates a URL with the edited values embedded.
ISO 286 Limits & Fits
The nominal diameter selects the ISO tolerance-grade row and, independently, the deviation step. The lower end of a step is exclusive and the upper end is inclusive. Minimum clearance equals hole minimum minus shaft maximum. Maximum clearance equals hole maximum minus shaft minimum.
A line-to-line endpoint belongs to the corresponding clearance or interference class. ISO leaves some grades and size combinations blank. Calculated fit assumes perfect geometry and ambient design dimensions.
Open calculatorGD&T True Position & Bonus
The diametral error is 2 × hypot(ΔX, ΔY). Bonus is the measured departure from the selected material limit if feature size is in tolerance. For X/Y, the two basic spans define a rectangle, and one shared radial datum shift rounds its corners. The same datum mobility cannot be used twice independently.
RFS means regardless of feature size. MMC and LMC mean maximum and least material condition. This 2D single-feature screen assumes free translation at one idealized datum. Verify datum precedence, simultaneous requirements, form, orientation, and functional gage boundaries against the drawing. ISO material requirements are specified in ISO 2692.
Open calculator1D Tolerance Stackup
Each link is recentered by (+ tolerance − lower tolerance magnitude) / 2 before combining. Worst-case adds signed extrema. Classical RSS uses the quadrature of drawing half widths; modified RSS applies the selected multiplier. Process RSS uses independent standard deviations derived from each link.
Normal links use σ = half-width / (3 × Cp). Uniform links use support half-width = half-width / spread factor and σ = that support / √3. Statistical envelopes assume independent variation. Check runout, contact geometry and correlated links separately.
Open calculatorProcess Capability Cp & Cpk
Cp and Cpk use the within-subgroup estimate; Pp, Ppk, Cpm and defect tails use overall sample sigma. With one specification side only, the width-based indices are undefined and the active one-sided index supplies Cpk and Ppk.
Normal-distribution tails estimate yield for a stable process. DPMO uses one opportunity per item. The optional +1.5 is a reporting convention added to the overall Z-bench, with no change to tails or capability indices.
Open calculatorGage R&R · Average & Range
This crossed study uses Average & Range. R̄̄ is the mean range across appraiser–part subgroups. X̄diff is the range of appraiser means. Rp is the range of part means. EV uses K₁ for the trial count and subgroup count, AV removes the repeatability term, and PV uses the K₃ part factor.
Use representative parts and blinded, randomized repeats. The method does not estimate appraiser × part interaction. A zero observed GRR gives no finite reliability estimate for ndc.
Open calculatorSurface Roughness Ra & Rz
Rt is the circular cusp height, capped at the nose radius at f ≥ 2r. Ra is the mean absolute height deviation about the integrated profile mean. The model uses circular arcs with a flat remaining crest beyond 2r. The inverse searches the rising circular-arc branch up to 2r.
Ratios between Ra, Rq, Rz and Rt depend on the actual profile and filter. N grades use legacy Ra levels. The capped model omits flank geometry, wear, chatter and material effects. Verify the actual filtered profile against the drawing.
Open calculatorMeasurement Uncertainty & Guard Band
Combine independent standard uncertainties in quadrature. Type A uses s / √n. Type B inputs use their stated distribution, including d / √12 for resolution. Differential thermal uncertainty includes uncertainty of CTE and temperature and their product term. Welch–Satterthwaite gives effective degrees of freedom.
The illustrated three-zone guard rule accepts values whose full ±U interval lies inside spec, rejects those wholly outside, and flags overlap. A contract may specify another rule, correlations, temperature correction or uncertainty coverage.
Open calculatorAQL Sampling & OC Curve
Z1.4 Table I maps lot size and inspection level to a code. The normal, tightened or reduced single-sampling table then resolves Ac, Re and arrow-directed sample size. For reduced inspection, counts strictly between Ac and Re accept this lot and reinstate normal inspection.
The lookup uses ANSI/ASQ Z1.4. ISO 2859-1 is a separate edition-specific scheme. Use the contract’s switching rules across lots. For a 100% sort the plotted chance is that the original lot is defect-free; replacement or disposition follows the inspection agreement.
Open calculator