Robot wrist seal squeeze
Worst-case / RSS / Modified RSS / SI units
- Nominal gap
- −0.35 mm
- Centered gap
- −0.35 mm
- Selected min
- −0.5317174 mm
- Selected max
- −0.1682826 mm
Inputs
- Target gap lower limit
- −0.52 mm
- Target gap upper limit
- −0.2 mm
- Decision basis
- Modified RSS
- Modified RSS factor
- 1.65
Dimension chain
- + Gland height
- 8.7 mm · +60 µm / −60 µm · normal · 1
- − Ring
- 6.85 mm · +65 µm / −65 µm · normal · 1
- − Backer
- 1.65 mm · +40 µm / −40 µm · normal · 1
- − Seal rise
- 0.55 mm · +52 µm / −52 µm · normal · 1
Gap envelopes
| Method | Minimum | Maximum | Target check |
|---|---|---|---|
| Worst-case | −0.567 mm | −0.133 mm | Out of spec |
| Classical RSS | −0.4601317 mm | −0.2398683 mm | In spec |
| Modified RSS | −0.5317174 mm | −0.1682826 mm | Out of spec |
| Process model · 3σ | −0.4601317 mm | −0.2398683 mm | In spec |
Contributions to process variance
| Link | Centered size | Half-width | σ | Share |
|---|---|---|---|---|
| + Gland height | 8.7 mm | 60 µm | 20 µm | 29.68 % |
| − Ring | 6.85 mm | 65 µm | 21.66667 µm | 34.83 % |
| − Backer | 1.65 mm | 40 µm | 13.33333 µm | 13.19 % |
| − Seal rise | 0.55 mm | 52 µm | 17.33333 µm | 22.29 % |
Interference across the selected envelope. The closest specification margin is −31.71737 µm. Normal links use σ = half-width / (3 × Cp). Uniform links use support half-width = half-width / spread factor and σ = that support / √3. Statistical envelopes assume independent variation. Check runout, contact geometry and correlated links separately.