Worked example · Live delivery
4K60 concert contribution over a 120 Mbps fiber uplink
A concert truck sends one UHD60 feed to a platform that transcodes the audience ladder. Fiber upload measures 0.12 Gbps and the engineering plan reserves 30% of that capacity.
Results
- Upload payload
- 32.668 Mbps
- Upload after reserve
- 84 Mbps
- Minimum measured upload
- 46.669 Mbps
- Source video target
- 32.348 Mbps
- Top rendition with audio
- 32.668 Mbps
- All rungs with audio
- 61.575 Mbps
- Top rung per viewer
- 14.701 GB/h
- Audience upper bound
- 1,470.067 GB/h
- Effective bits/pixel/frame
- 0.065 bits
51.332 Mbps under the reserved upload budget.
| Rendition | Frame rate | Video Mbps | With audio Mbps |
|---|---|---|---|
| 4K | 60 | 32.348 | 32.668 |
| 1440p | 60 | 14.377 | 14.697 |
| 1080p | 60 | 8.087 | 8.407 |
| 720p | 60 | 3.594 | 3.914 |
| 480p | 30 | 0.799 | 1.119 |
| 360p | 30 | 0.449 | 0.769 |
Input settings
- Highest resolution
- 4K · 3840 × 2160
- Source frame rate
- 60 fps
- Scene motion
- Mixed · ×1
- Base bits/pixel/frame
- 0.065
- Audio per rendition (kbps)
- 320
- Concurrent viewers
- 100
- Measured upload
- 0.12
- Upload unit
- Gbps
- Reserved upload (%)
- 30
- Contribution mode
- Single ingest
Try a change
Switch from Single ingest to Upload all rungs to estimate what the uplink would carry with local parallel packaging.
Questions
Can this 4K60 bitrate model tell me the platform’s allowed bitrate?
Use the platform’s current encoder specification for the codec, frame rate and maximum bitrate. This workflow sizes the payload using a chosen bit budget.
Why keep 30% spare on a fiber uplink whose speed looks stable?
The reserve leaves space for short-term variation, transport overhead, monitoring, and other venue traffic. A pre-event sustained test is more informative than a burst result.