Worked example · Broadcast timing
29.97 DF at a ten-minute break marker
An automation engineer has an event at frame 17,982 measured from the start of a 29.97 DF programme. They need the actual event label and its wall-clock error.
Results
- Resulting timecode
- 00:10:00;00
- Frame index or interval
- 17,982 frames
- Elapsed wall time
- 9 min 59.999 s
- Exact rate (rounded)
- 29.97 fps
- Same frames in DF
- 00:10:00;00
- Same frames in NDF
- 00:09:59:12
- DF wall − label
- -0.6 ms
- NDF wall − label
- +599.4 ms
The first 2 frame labels are omitted in non-tenth minutes.
Input settings
- Timecode rate
- 29.97 DF fps
- Operation
- Frames to code
- Output timecode format
- Signed elapsed
- Frame index from zero
- 17982
Try a change
Subtract one from the frame index. The previous label is 00:09:59;29, so the rollover at the tenth minute keeps label 00.
Questions
Is 00:10:00;00 a legal drop-frame label?
Yes. Minutes divisible by ten keep the first two labels and the remaining minutes skip them.
Is the 29.97 DF ten-minute boundary exactly ten wall-clock minutes?
The boundary occurs at 599.9994 seconds on the nominal NTSC time base, 0.6 ms before ten minutes.