Worked example · Post storage
Twelve-drive RAID 50 with three parity groups
A finishing house stripes three four-drive RAID 5 groups using 18 TB disks. A single drive measures 240 MB/s and the shared storage link is capped at 1,200 MB/s.
Results
- Usable storage
- 162 TB
- Maximum whole streams
- 9 streams
- Usable binary storage
- 147.338 TiB
- Raw storage
- 216 TB
- Raw binary storage
- 196.451 TiB
- Redundancy overhead
- 54 TB
- Modeled read bandwidth
- 1,200 MB/s
- Read per drive
- 240 MB/s
Survives 1 failed drive in any position, or up to 3 when distributed across groups.
Input settings
- Drive count
- 12
- Capacity per drive (TB)
- 18
- RAID level
- RAID 50
- Equal parity groups
- 3
- Single-drive read profile
- Measured MB/s
- Single-drive read (MB/s)
- 240
- Read efficiency (%)
- 75
- Link read cap (MB/s)
- 1200
- Bitrate per editing stream
- 1000
- Stream-rate unit
- Mbps
Try a change
Change to two groups of six. Check how the space increases while the number of isolated groups and best-case failed-drive count decrease.
Questions
Can the three-group RAID 50 survive three arbitrary failures?
It can survive three when each parity group loses one drive. Two failed drives in the same RAID 5 group would lose data.
Why do twelve disks provide nine data-drive equivalents in this RAID 50?
Each of the three groups reserves the equivalent of one drive for distributed parity.