70 V Speaker Line With Twelve 5 W Taps and Two 10 W Taps
A paging run has twelve speakers tapped at 5 W and two at 10 W. Enter the twelve repeated taps first and put 20 W in the additional tap field.
- One-way cable length
- 160 ft
- Cable gauge
- 16 AWG
- Compare with
- 14 AWG
- Parallel conductors per leg
- 1
- Copper temperature
- 68 °F
- Speaker load
- 4 Ω
- Rated amplifier damping factor
- 200
- Amplifier DF reference load
- 8 Ω
- Constant-voltage line
- 70.7 V (70 V nominal)
- Equal transformer taps
- 12
- Power per equal tap
- 5 W
- Additional tap total
- 20 W
- Line amplifier reserve
- 1 dB
Results
- Total line transformer taps
- 80W
- Equivalent transformer load
- 62.48Ω
- Line amplifier power with reserve
- 100.71W
- Cable loop resistance
- 1.285Ω
- Speaker insertion loss
- 2.42dB
- Effective damping factor
- 3
- Reduction in speaker power
- 42.72%
- 14 AWG comparison loss
- 1.598dB
- Amplifier output resistance
- 0.04Ω
- Farthest load voltage drop
- 1.42V
- Farthest load delivered power
- 76.81W
Dots show the two gauges at the entered length. The model compares speaker power at fixed amplifier terminal voltage.
The line diagram combines the transformer taps at the far end of the modeled cable.
Same-run copper wire comparison
| Gauge | Loop R (Ω) | Loss (dB) | Power at speaker (%) |
|---|---|---|---|
| 16 AWG | 1.285 | 2.42 | 57.28 |
| 14 AWG | 0.8081 | 1.598 | 69.21 |
Worked calculation
Add transformer taps on the line
Ptotal = 12 × 5 + 20 = 80 W. Rload = 70.7² ÷ 80 = 62.481 Ω
Add line amplifier reserve
Pamp = 80 × 10^(1 ÷ 10) = 100.714 W
Use the outgoing and return conductors
Rloop = ρ(T) × 2 × 48.768 m ÷ (1.3087 mm² × 1) = 1.28496 Ω
What the example shows
The total is 80 W at the nominal line voltage. One dB of reserve brings the capacity target to about 101 W before choosing an amp rating.
Model assumptions
- Resistance assumes annealed copper with equal outgoing and return lengths. Parallel conductors are counted per leg. Cable loss compares speaker power at a fixed amplifier terminal voltage.
- Effective damping uses the amp damping factor at its stated reference load to infer amp source resistance. The speaker is modeled as a resistive nominal load.
- The distributed-line estimate places the combined taps at the far end of the selected cable. Real distributed loads draw current along the route, so voltage drop is location-dependent.
Common questions
Do the two 10 W speakers count as 10 or 20 additional watts?
They total 20 W. The worksheet adds that to 12 × 5 W for 80 W total.
Why does this 70 V example use 70.7 V?
It uses the common 70.7 Vrms nominal convention. The equivalent load is calculated from the square of that voltage divided by the tap total.