70 V Speaker Line With Twelve 5 W Taps and Two 10 W Taps

A paging run has twelve speakers tapped at 5 W and two at 10 W. Enter the twelve repeated taps first and put 20 W in the additional tap field.

Inputs

Cable run and speaker
ft
°F
Ω
Ω
70 V / 100 V transformer line
W
W
dB

Results

Total line transformer taps
80W
Equivalent transformer load
62.48Ω
Line amplifier power with reserve
100.71W
Cable loop resistance
1.285Ω
Speaker insertion loss
2.42dB
Effective damping factor
3
Reduction in speaker power
42.72%
14 AWG comparison loss
1.598dB
Amplifier output resistance
0.04Ω
Farthest load voltage drop
1.42V
Farthest load delivered power
76.81W
Speaker cable loss by run length
Speaker cable loss by run lengthInsertion loss (dB)06412819225632001.212.413.624.83One-way run (ft)16 AWG14 AWG

Dots show the two gauges at the entered length. The model compares speaker power at fixed amplifier terminal voltage.

Distributed transformer-line equivalent
Distributed transformer-line equivalent70.7 V RMS80 W taps62.48 ΩCable loopFarthest-load drop ≈ 1.425 V

The line diagram combines the transformer taps at the far end of the modeled cable.

Same-run copper wire comparison

GaugeLoop R (Ω)Loss (dB)Power at speaker (%)
16 AWG1.2852.4257.28
14 AWG0.80811.59869.21

Worked calculation

  1. Add transformer taps on the line

    Ptotal = 12 × 5 + 20 = 80 W. Rload = 70.7² ÷ 80 = 62.481 Ω

  2. Add line amplifier reserve

    Pamp = 80 × 10^(1 ÷ 10) = 100.714 W

  3. Use the outgoing and return conductors

    Rloop = ρ(T) × 2 × 48.768 m ÷ (1.3087 mm² × 1) = 1.28496 Ω

What the example shows

The total is 80 W at the nominal line voltage. One dB of reserve brings the capacity target to about 101 W before choosing an amp rating.

Model assumptions

  • Resistance assumes annealed copper with equal outgoing and return lengths. Parallel conductors are counted per leg. Cable loss compares speaker power at a fixed amplifier terminal voltage.
  • Effective damping uses the amp damping factor at its stated reference load to infer amp source resistance. The speaker is modeled as a resistive nominal load.
  • The distributed-line estimate places the combined taps at the far end of the selected cable. Real distributed loads draw current along the route, so voltage drop is location-dependent.