A 48-inch belt receives fractured basalt under a primary crusher. The drive estimate includes an allowance for skirt resistance near the loading point.
A = h(c + a) + R²(θ − sin θ cos θ)
Qᵥ = 3,600 A v | Qₘ = Qᵥ ρ / 1,000
Three equal-roll trough geometry, with center roll width c = B/3 and usable belt width 0.9B − 2 in. The loaded wings have horizontal projection a and rise h. Surcharge θ is the edge tangent angle of a circular cap, with R = (c + 2a)/(2 sin θ). The cap vanishes at 0°. Match the actual idlers, edge clearance and loading condition for detailed work.
Historical CEMA running tension
Tₑ = L Kt [Kx + (Ky + 0.015) Wb] + Wm (L Ky + H) + Taux
Kx is idler resistance per unit length, Wb and Wm are belt and material weights per unit length, L is centerline length, and H is lift. Use consistent force and length units. Enter pulley, skirt and loading components as one ancillary running pull. The starting, stopping, take-up, sag and rollback checks require a separate conveyor design.
Use wrap θ in radians and Tₑ in newtons with v in m/s for kW. The tensions are the ideal minimum pair at incipient slip. Belt rating, take-up and traction allowances must be established for the installation.
Geometry only. Check rollback and belt rating separately.
Inputs
Belt width
48 in
Trough angle
45°
Surcharge angle
26°
Bulk density
112 lb/ft³
Belt speed
510 FPM
Belt length
210 ft
Vertical lift
30 ft
Drive pulley wrap
200°
Pulley friction μ
0.35
Belt mass per length
14 lb/ft
Idler resistance Kx
0.35 lbf/ft
Flexure factor Ky
0.03
Temperature factor Kt
1
Other running pull
180 lbf
Drive efficiency
93%
Calculated values
Mass throughput
3,699.484TPH
Motor power
152.269HP
Effective tension Te
9,163.007lbf
Minimum tight side T1
12,992.008lbf
Minimum slack side T2
3,829.001lbf
Minimum traction T1/T2
3.393
Load cross-section
2.159ft²
Area inside trough
1.541ft²
Area above trough
0.618ft²
Volume throughput
66,062.212CFH
Running resistance
1,909.117lbf
Lift tension
7,253.89lbf
Pulley shaft power
141.61HP
Conveyor incline
8.213°
Industrial machinery and mobile equipment can cause fatal injuries. Use these estimates for preliminary sizing. Follow the MSHA or OSHA requirements that apply at your site. Guard moving parts and nip points, and use site lockout/tagout and hazardous-energy isolation procedures before service. Have qualified personnel verify equipment selection and operating limits.