Sullivan residence-time approximation

Rotary Drum Residence Time & Fill Calculator

Estimate rotary drum retention time, holdup, cross-sectional fill and volumetric throughput for a dryer or kiln.

Live results

Sloped drum, bed section and fill band

Edit inputs
Sloped drum, bed section and fill band Four live readings and a schematic of the selected material-handling configuration. Full values follow the diagram. RESIDENCE7.69minDRUM FILL6%HOLDUP MASS6.92short tonsRIM SPEED100.53FPM DRUM ELEVATIONBED SECTION54 ft active length0.5 in/ft fall8 ft inside Ø33° repose Occupied cross-section6%Under-fill. Below the 8% reference.

Under-fill. Below the 8% reference.

All calculated values
Mean residence time
7.695min
Cross-sectional fill
5.996%
Solids holdup mass
6.917short tons
Peripheral speed
100.531FPM
Volumetric throughput
47yd³/h
Solids holdup volume
6.028yd³
Active drum volume
100.531yd³
Occupied cross-section
3.014ft²
Throughput at 8% fill
62.709yd³/h
Throughput at 15% fill
117.58yd³/h
Incline angle
2.386°

Inputs

Unit system
Operating inputs
ft
ft
in/ft
Downhill slope. The equation uses rise/run, converted from in/ft or degrees.
RPM
yd³/h
lb/ft³
°

Worked examples

Open and edit any starting case

Equations and assumptions

Simplified Sullivan residence time

t = 0.19 L / (N D S)   |   S = tan α = (in/ft)/12

L and D may both be metres or both be feet. N is rpm, S is rise over horizontal run, and t is minutes. This handbook form uses a fixed 0.19 coefficient. The entered repose angle sets the drawn bed orientation. Material-specific residence time depends on repose, flights, dams, conveying action and gas flow.

Holdup, fill and rim speed

Vhold = Qᵥ t/60   |   Vdrum = πD²L/4
Fill = 100 Vhold/Vdrum   |   Mhold = ρ Vhold   |   v = πDN/60

Steady-state holdup uses Qᵥ in m³/h. Cross-sectional fill is an average for a uniform inside diameter. The 8–15% visual window is a preliminary loading reference and identifies under-fill and potential cascading overload. A computed fill above 100% signals an infeasible steady-state estimate.

References