Worked example · Rotary Drum

Aggregate dryer in the nominal fill band

An eight-foot aggregate dryer turns at 4 RPM with half an inch of fall per foot of horizontal run.

Live results

Sloped drum, bed section and fill band

Edit inputs
Sloped drum, bed section and fill band Four live readings and a schematic of the selected material-handling configuration. Full values follow the diagram. RESIDENCE7.69minDRUM FILL9.19%HOLDUP MASS10.6short tonsRIM SPEED100.53FPM DRUM ELEVATIONBED SECTION54 ft active length0.5 in/ft fall8 ft inside Ø33° repose Occupied cross-section9.19%Within the 8–15% reference band.

Within the 8–15% reference band.

All calculated values
Mean residence time
7.695min
Cross-sectional fill
9.185%
Solids holdup mass
10.596short tons
Peripheral speed
100.531FPM
Volumetric throughput
72yd³/h
Solids holdup volume
9.234yd³
Active drum volume
100.531yd³
Occupied cross-section
4.617ft²
Throughput at 8% fill
62.709yd³/h
Throughput at 15% fill
117.58yd³/h
Incline angle
2.386°

Inputs

Unit system
Operating inputs
ft
ft
in/ft
Downhill slope. The equation uses rise/run, converted from in/ft or degrees.
RPM
yd³/h
lb/ft³
°

Worked solution

Starting case in US units

  1. Convert 0.5 in/ft to rise/run. The 54 ft active length, 8 ft diameter and 4 RPM give 7.69 min residence time.
  2. Feed at 72 yd³/h accumulates 9.23 yd³ of solids. Divide by 100.53 yd³ drum volume to get 9.19% fill.
  3. At 85 lb/ft³ bulk density, holdup is 10.6 short tons. The reference fill band corresponds to 62.71 yd³/h through 117.58 yd³/h.

Try it. Compare the current feed with the rates corresponding to 8% and 15% fill. Check that their residence time basis is the same.

More worked examples

Open a different starting case

Equations and assumptions

Simplified Sullivan residence time

t = 0.19 L / (N D S)   |   S = tan α = (in/ft)/12

L and D may both be metres or both be feet. N is rpm, S is rise over horizontal run, and t is minutes. This handbook form uses a fixed 0.19 coefficient. The entered repose angle sets the drawn bed orientation. Material-specific residence time depends on repose, flights, dams, conveying action and gas flow.

Holdup, fill and rim speed

Vhold = Qᵥ t/60   |   Vdrum = πD²L/4
Fill = 100 Vhold/Vdrum   |   Mhold = ρ Vhold   |   v = πDN/60

Steady-state holdup uses Qᵥ in m³/h. Cross-sectional fill is an average for a uniform inside diameter. The 8–15% visual window is a preliminary loading reference and identifies under-fill and potential cascading overload. A computed fill above 100% signals an infeasible steady-state estimate.