Calculators
Rotary Drum Worked example
Worked example · Rotary Drum
Higher-speed rotary cooler
A rotary cooler uses higher speed to limit residence time at increased throughput.
Live results Sloped drum, bed section and fill band
Edit inputs
Sloped drum, bed section and fill band
Four live readings and a schematic of the selected material-handling configuration. Full values follow the diagram.
RESIDENCE 3.44 min DRUM FILL 5.76 % HOLDUP MASS 8.98 short tons RIM SPEED 197.92 FPM
DRUM ELEVATION BED SECTION 57 ft active length 0.6 in/ft fall 9 ft inside Ø 32° repose
Occupied cross-section 5.76% Under-fill. Below the 8% reference.
Under-fill. Below the 8% reference.
Share link JSON CSV SVG PNG Print / PDF
Shareable link
All calculated values
Mean residence time 3.438 min
Cross-sectional fill 5.76 %
Solids holdup mass 8.981 short tons
Peripheral speed 197.92 FPM
Volumetric throughput 135 yd³/h
Solids holdup volume 7.736 yd³
Active drum volume 134.303 yd³
Occupied cross-section 3.664 ft²
Throughput at 8% fill 187.503 yd³/h
Throughput at 15% fill 351.569 yd³/h
Incline angle 2.862 °
Worked solution Starting case in US units
Convert 0.6 in/ft to rise/run. The 57 ft active length, 9 ft diameter and 7 RPM give 3.44 min residence time. Feed at 135 yd³/h accumulates 7.74 yd³ of solids. Divide by 134.3 yd³ drum volume to get 5.76% fill. At 86 lb/ft³ bulk density, holdup is 8.98 short tons. The reference fill band corresponds to 187.5 yd³/h through 351.57 yd³/h.
Try it. Change the material repose angle to see the drawn bed rotate, then adjust RPM to see the actual residence time response.
More worked examples
Open a different starting case
Industrial machinery safety
Industrial machinery and mobile equipment can cause fatal injuries. Use these estimates for preliminary sizing. Follow the MSHA or OSHA requirements that apply at your site. Guard moving parts and nip points, and use site lockout/tagout and hazardous-energy isolation procedures before service. Have qualified personnel verify equipment selection and operating limits.
MSHA conveyor guarding · OSHA machine guarding · OSHA lockout/tagout
Back to Rotary Drum
BulkConveyorLab
Higher-speed rotary cooler
Sullivan residence-time approximation
Sloped drum, bed section and fill band
Four live readings and a schematic of the selected material-handling configuration. Full values follow the diagram.
RESIDENCE 3.44 min DRUM FILL 5.76 % HOLDUP MASS 8.98 short tons RIM SPEED 197.92 FPM
DRUM ELEVATION BED SECTION 57 ft active length 0.6 in/ft fall 9 ft inside Ø 32° repose
Occupied cross-section 5.76% Under-fill. Below the 8% reference.
Under-fill. Below the 8% reference.
Inputs
Drum inside diameter
9 ft
Drum active length
57 ft
Drum incline
0.6 in/ft
Drum rotation speed
7 RPM
Volumetric feed
135 yd³/h
Bulk density
86 lb/ft³
Material angle of repose
32° Calculated values
Mean residence time 3.438 min
Cross-sectional fill 5.76 %
Solids holdup mass 8.981 short tons
Peripheral speed 197.92 FPM
Volumetric throughput 135 yd³/h
Solids holdup volume 7.736 yd³
Active drum volume 134.303 yd³
Occupied cross-section 3.664 ft²
Throughput at 8% fill 187.503 yd³/h
Throughput at 15% fill 351.569 yd³/h
Incline angle 2.862 °
Industrial machinery and mobile equipment can cause fatal injuries. Use these estimates for preliminary sizing. Follow the MSHA or OSHA requirements that apply at your site. Guard moving parts and nip points, and use site lockout/tagout and hazardous-energy isolation procedures before service. Have qualified personnel verify equipment selection and operating limits.
https://calcsheetlab.com/bulkconveyorlab/rotary-drum-residence-time-calculator/high-speed-rotary-cooler/
{"tool":{"id":"drum","anatomy":"Sloped drum, bed section and fill band","metrics":[["residence","Mean residence time","time","RESIDENCE"],["fill","Cross-sectional fill","percent","DRUM FILL"],["mass","Solids holdup mass","mass","HOLDUP MASS"],["speed","Peripheral speed","speed","RIM SPEED"],["feed","Volumetric throughput","drumRate"],["holdup","Solids holdup volume","volume"],["capacity","Active drum volume","volume"],["filledArea","Occupied cross-section","area"],["lowFeed","Throughput at 8% fill","drumRate"],["highFeed","Throughput at 15% fill","drumRate"],["slopeAngle","Incline angle","angle"]],"fields":[{"key":"diameter","label":"Drum inside diameter","kind":"length","initial":2.4384,"min":0.1524,"max":18.288},{"key":"length","label":"Drum active length","kind":"length","initial":16.4592,"min":0.3048,"max":304.8},{"key":"slope","label":"Drum incline","kind":"slope","initial":0.041666666666666664,"min":0.0008333333333333333,"max":0.25,"help":"Downhill slope. The equation uses rise/run, converted from in/ft or degrees."},{"key":"rpm","label":"Drum rotation speed","kind":"rpm","initial":4,"min":0.1,"max":60},{"key":"feed","label":"Volumetric feed","kind":"drumRate","initial":35.93407832524801,"min":0.0007645548579840002,"max":3822.774289920001},{"key":"density","label":"Bulk density","kind":"density","initial":1361.5693867866116,"min":16.018463373960138,"max":6407.385349584055},{"key":"repose","label":"Material angle of repose","kind":"angle","initial":33,"min":10,"max":60}]},"initial":{"diameter":2.7432000000000003,"length":17.3736,"slope":0.049999999999999996,"rpm":7,"feed":103.21490582784003,"density":1377.5878501605719,"repose":32},"title":"Higher-speed rotary cooler","route":"/rotary-drum-residence-time-calculator/high-speed-rotary-cooler/"}