R and r are base and top radii. The cone has r = 0. The input repose angle is measured up from horizontal. Measure its actual slope where the pile profile or material varies.
The rounded ends are two half-cones. The straight middle is a triangular prism with base width 2R. End-to-end length includes both rounded ends. This geometry assumes level ground and a straight, level crest.
Enter as-stockpiled wet bulk density and wet-basis water fraction w. The last load is often partial. Actual payload depends on equipment, site conditions and applicable weight limits.
BulkConveyorLab
Short coarse-rock windrow
Cone / frustum / windrow geometry
Truck count uses wet mass and the entered payload.
Inputs
Stockpile geometry
Round-end windrow
Base width / diameter
52 ft
Top diameter
28 ft
End-to-end length
80 ft
Angle of repose
42°
Bulk density
99 lb/ft³
Wet-basis moisture
2%
Truck payload
24 short tons
Calculated values
Stockpile volume
1,245.01yd³
Wet pile mass
1,663.956short tons
Dry solids mass
1,630.677short tons
Truckloads
70
Calculated pile height
23.411ft
Base footprint
3,579.717ft²
Cone, frustum or end volume
613.794yd³
Straight windrow volume
631.217yd³
Water mass
33.279short tons
Final truck payload used
33.15%
Industrial machinery and mobile equipment can cause fatal injuries. Use these estimates for preliminary sizing. Follow the MSHA or OSHA requirements that apply at your site. Guard moving parts and nip points, and use site lockout/tagout and hazardous-energy isolation procedures before service. Have qualified personnel verify equipment selection and operating limits.