R and r are base and top radii. The cone has r = 0. The input repose angle is measured up from horizontal. Measure its actual slope where the pile profile or material varies.
The rounded ends are two half-cones. The straight middle is a triangular prism with base width 2R. End-to-end length includes both rounded ends. This geometry assumes level ground and a straight, level crest.
Enter as-stockpiled wet bulk density and wet-basis water fraction w. The last load is often partial. Actual payload depends on equipment, site conditions and applicable weight limits.
BulkConveyorLab
Dry sand cone at 30° repose
Cone / frustum / windrow geometry
Truck count uses wet mass and the entered payload.
Inputs
Stockpile geometry
Cone
Base width / diameter
60 ft
Top diameter
28 ft
End-to-end length
170 ft
Angle of repose
30°
Bulk density
96 lb/ft³
Wet-basis moisture
0%
Truck payload
25 short tons
Calculated values
Stockpile volume
604.6yd³
Wet pile mass
783.561short tons
Dry solids mass
783.561short tons
Truckloads
32
Calculated pile height
17.321ft
Base footprint
2,827.433ft²
Cone, frustum or end volume
604.6yd³
Straight windrow volume
0yd³
Water mass
0short tons
Final truck payload used
34.245%
Industrial machinery and mobile equipment can cause fatal injuries. Use these estimates for preliminary sizing. Follow the MSHA or OSHA requirements that apply at your site. Guard moving parts and nip points, and use site lockout/tagout and hazardous-energy isolation procedures before service. Have qualified personnel verify equipment selection and operating limits.