Eight 1:2 Dilutions at 200 µL per Tube
Build an eight-step twofold dilution from 1,600 nM and check the stock, transfer, diluent and endpoint concentrations.
Cₙ = C₀ ÷ fⁿ
Bench result
Calculated in this browser
- Dilution type
- Serial dilution
- Stock concentration
- 1600
- Concentration unit for both
- nM
- Mixed fill volume
- 200
- Volume unit
- µL
- Number of steps
- 8
- Dilution per step
- 1:2
- Transfer per tube
- 100µL
- Diluent per tube
- 100µL
- Final concentration
- 6.25nM
- Volume left in first tube
- 100µL
| Tube | Conc.nM | TransferµL | DiluentµL | LeftµL |
|---|---|---|---|---|
| 1 | 800 | 100 | 100 | 100 |
| 2 | 400 | 100 | 100 | 100 |
| 3 | 200 | 100 | 100 | 100 |
| 4 | 100 | 100 | 100 | 100 |
| 5 | 50 | 100 | 100 | 100 |
| 6 | 25 | 100 | 100 | 100 |
| 7 | 12.5 | 100 | 100 | 100 |
| 8 | 6.25 | 100 | 100 | 200 |
Worked calculation
Set up each tube
For a 1:2 dilution, Vtransfer = 200 ÷ 2 = 100 µL. Mix each stage before transferring from it.
Find diluent volume
Vdiluent = 200 − 100 = 100 µL.
Repeat the dilution factor
C8 = 1,600 ÷ 2^8 = 6.25 nM. Intermediate tubes retain 100 µL after transfer.
- Use a compatible diluent. The mixed fill is the volume before the next transfer. The last tube retains its full mixed fill.
How the model works
Use a common concentration unit for both solutions and a common volume unit for the transfer and total. For a serial dilution, each well-mixed tube provides the input for the next.
Frequently asked questions
Does the undiluted 1,600 nM sample count as the first step?
Count the undiluted sample as the stock. Tube 1 is the first mixed dilution at 800 nM.
Which tube in the twofold series contains 100 nM?
Tube 4, because 1,600 nM divided by 2⁴ equals 100 nM.