Greenhouse math for better growing.
Plan your climate, lighting, nutrients and planting space with practical calculators and editable worked examples.
Calculations run in your browser
78°F · 60% relative humidity
Vegetative band · −2°F leaf offset · Select a cell
Calculators
Choose a tool to model your growing space.
- Climate
VPD & dew point
Calculate air and leaf vapor pressure deficit in kPa, find dew point and explore temperature and humidity on an interactive growth-stage heatmap.
- Lighting
DLI & grow lights
Convert PPFD and photoperiod to daily light integral. Estimate LED wattage, canopy coverage, fixture count and monthly electricity cost.
- Hydroponics
Nutrients, EC & PPM
Convert hydroponic EC to 500 or 700 scale PPM, mix multi-part nutrients and estimate reservoir EC after adding water or feed.
- Climate
Exhaust & air exchange
Estimate required grow tent or greenhouse airflow in CFM and m³/h with carbon filter, duct length, elbow and air-exchange adjustments.
- Climate
Greenhouse heating
Size greenhouse heat output in BTU/hr or kW from exposed glazing area, design temperature, wind allowance and glazing U-value.
- Climate
CO₂ enrichment
Estimate greenhouse CO₂ fill time, injection flow, duty cycle and 20 lb or 50 lb cylinder duration from room volume and a horticultural ppm target.
- Garden planning
Soil & mix volumes
Find cubic feet, cubic yards, liters and bag counts for raised beds, straight or tapered containers, mulch and custom compost blends.
- Garden planning
Spacing, seeds & yield
Compare square and staggered plant spacing, count greenhouse bench stations, plan seed reserves and estimate harvest with an interactive layout.
Worked examples
Open a scenario to see the math and adjust the inputs to match your setup.
VPD & dew point7 guides
DLI & grow lights7 guides
- 600 PPFD for 18 hours and LED wattage for a 4×4 tent
- Lettuce DLI from 300 PPFD for 16 hours
- Add 200 PPFD to 8 mol of greenhouse sunlight DLI
- Grow light coverage at 400 PPFD in a 3×3 area
- 750 PPFD for 12 hours on a fruiting canopy
- Cutting propagation DLI from 150 PPFD for 18 hours
- Monthly LED electricity cost for a 5×5 growing area
Nutrients, EC & PPM7 guides
- 2.0 EC to 500- and 700-scale PPM in a 20-gallon reservoir
- Convert 840 ppm on the 700 scale to EC
- Dilute a half-full 20-gallon hydroponic reservoir
- Dose Part A, Part B and supplement in 55 liters
- Why a nearly full 40-gallon reservoir cannot reach target EC
- Find top-off EC for an 80-liter reservoir at 1.6 EC
- Convert 1,000 ppm on the 500 scale and dose a 10-gallon batch
Exhaust & air exchange6 guides
Greenhouse heating6 guides
CO₂ enrichment5 guides
Soil & mix volumes6 guides
Spacing, seeds & yield6 guides
- Triangular vs. square 12-inch spacing in a 4×12 bed
- Eight-inch staggered lettuce spacing in a 4×8 bed
- Trellised tomato rows and seed reserve in a 4×12 bed
- Six-inch plant capacity across three 24×4 greenhouse benches
- Basil bench layout at 16 cm spacing and estimated yield
- Seed reserve for a 3×6 bed at 70% germination