Cleanroom particle limits & FFU sizing

Check ISO Class 3–8 particle limits, supply airflow, HEPA fan-filter units and ideal recovery time.

Inputs

Room geometry
ft
ft
ft
Supply & ceiling
h⁻¹
CFM
Use the rated flow at the planned operating pressure.

Live results

Ceiling grid and particle curve

Ceiling grid and particle curveSUPPLY FLOW5,508CFMAIR CHANGES85h⁻¹FFU COUNT9unitsCOVERAGE16.67%FFU ceiling gridMixed-air supplyISO 7 · particles/m³110⁴10⁸0.10.20.30.515µmUniform ceiling fitFFU count9 neededGrid 54 units
Filled ceiling cells represent the share covered by FFUs. Hollow circles on the particle curve mark formula-only values.

The required FFU count fits the uniform grid before service clearances.

Supply flow
5,508 CFM
Air changes
85 h⁻¹
FFU count
9 units
Coverage
16.6667 %

Room and airflow

Floor area
432 ft²
Room volume
3,888 ft³
Installed FFU capacity
5,850 CFM
Capacity above target
342 CFM
100:1 ideal recovery
3.25071 min

Ceiling layout

Installed FFU face area
72 ft²
Uniform grid capacity
54 units

Particle concentrations (particles/m³)

ThresholdFormulaISO table limit
≥ 0.1 µm10,000,000Unassigned
≥ 0.2 µm2,365,144Unassigned
≥ 0.3 µm1,017,625Unassigned
≥ 0.5 µm351,675.7352,000
≥ 1 µm83,176.3883,200
≥ 5 µm2,925.1112,930

Counts are cumulative. Use the published classification value for each applicable class and particle size.

Equations and assumptions

Particle concentration

Cₙ = 10ᴺ × (0.1 ÷ D)²·⁰⁸

D is the threshold particle size in µm. Each value includes particles at or above D and is reported in particles/m³. Formula values are shown for all six sizes. Use the separate ISO 14644-1:2015 Table 1 column when a class/size limit is published.

Supply airflow

Q = A × H × ACH ÷ 3600 or Q = A × v

Use SI dimensions (m and m²), v in m/s and Q in m³/s. The unidirectional case assumes flow over the full floor plan. The selected ISO class sets particle criteria independently of the airflow target.

FFU count and ceiling fit

n = ceil(Q ÷ Q_FFU) · coverage = n × A_FFU ÷ A × 100%

Grid capacity uses the better of two uniform module orientations. Lights, sprinklers, service clearance and mixed-orientation layouts need a separate ceiling plan.

100:1 recovery

t₁₀₀ = 60 × ln(100) ÷ ACH

This minute estimate assumes perfect mixing, no continuing source and contaminant-free supply. Measure recovery when applicable under ISO 14644-3. For unidirectional flow it remains a mixed-air benchmark.