Worked example

Asymmetric 0₂/90₂ carbon skin

Load the asymmetric stack in x with no applied moments.

B is nonzero and the membrane load induces curvature. Reverse the stack to see the sign of B reverse.

View live results

Inputs

Ply material
GPa
GPa
GPa
g/cm³
Ply stack

Enter blocks from the bottom face to the top face.

1
2
Membrane loads
N/mm
N/mm
N/mm
Moments per unit width
N
N
N

Live results

SI
Thickness
0.5 mm
Membrane Ex
33.518 GPa
Bending Ex,f
33.518 GPa
Areal mass
790 g/m²
Extension–bending coupledCoupling assessed relative to membrane and bending stiffness
Laminate edge section
Scaled laminate stack and thickness-weighted fiber orientation composition +z / TOP−z / BASE0.5 mm0°50%±45°0%90°50%Other0%
  • 0°
  • ±45°
  • 90°
  • Other
0° fiber thickness share50%
0%100% of stack

Engineering constants

Membrane Ey
33.5183 GPa
Membrane Gxy
7.2 GPa
Membrane νxy
0.03652
Bending Ey,f
33.5183 GPa
Ply count
4
max |Bᵢⱼ|
4,137.5 N

Mid-plane response

ε⁰ x
4,475.17 µε
ε⁰ y
−163.433 µε
ε⁰ xy
0 µε
κ x
0.0232192 mm⁻¹
κ y
0 mm⁻¹
κ xy
0 mm⁻¹

ABD stiffness A N/mm · B N · D N·mm

εxεyγxyκxκyκxy
Nx38,2801,3980−4,13800
Ny1,39838,280004,1380
Nxy003,600000
Mx−4,13800797.429.120
My04,138029.12797.40
Mxy0000075

Model and assumptions

A = ΣQ̄ Δz · B = ½ΣQ̄ Δ(z²) · D = ⅓ΣQ̄ Δ(z³) · [N; M] = [A B; B D][ε⁰; κ].

Enter blocks from the bottom face (negative z) to the top face (positive z). Ply count multiplies the thickness of a single ply. The composition is weighted by thickness and “other” contains angles outside 0°, ±45° and 90°.

The bank uses one material and one density for the full stack. Membrane constants come from the upper-left compliance block of the inverted ABD matrix at M = 0. The flexural modulus uses the lower-right compliance block at N = 0.

The coupling flag compares |Bᵢⱼ|/√(AᵢᵢDⱼⱼ) with numerical roundoff. Mirrored layups have B = 0 by symmetry. An unbalanced laminate can still have A₁₆ or A₂₆ even with zero B.

Scope. Thin, perfectly bonded, linear elastic plies. Inputs are purely mechanical resultants, with no transverse shear, thermal load or interlaminar stress recovery.

See calculation methods and references