Worked example

Balanced angle-ply shell strip

Compare extension coupling and extension–bending coupling in a balanced but asymmetric angle-ply shell strip.

Equal amounts of +45° and −45° cancel A₁₆ and A₂₆ while the different stacking positions leave a nonzero B.

View live results

Inputs

Ply material
GPa
GPa
GPa
g/cm³
Ply stack

Enter blocks from the bottom face to the top face.

1
2
3
Membrane loads
N/mm
N/mm
N/mm
Moments per unit width
N
N
N

Live results

SI
Thickness
0.84 mm
Membrane Ex
23.982 GPa
Bending Ex,f
21.96 GPa
Areal mass
1,327.2 g/m²
Extension–bending coupledCoupling assessed relative to membrane and bending stiffness
Laminate edge section
Scaled laminate stack and thickness-weighted fiber orientation composition +z / TOP−z / BASE0.84 mm0°0%±45°100%90°0%Other0%
  • 0°
  • ±45°
  • 90°
  • Other
0° fiber thickness share0%
0%100% of stack

Engineering constants

Membrane Ey
23.9819 GPa
Membrane Gxy
33.3121 GPa
Membrane νxy
0.665408
Bending Ey,f
21.9604 GPa
Ply count
6
max |Bᵢⱼ|
1,946.28 N

Mid-plane response

ε⁰ x
84.4134 µε
ε⁰ y
84.4134 µε
ε⁰ xy
752.971 µε
κ x
−4.30019e-4 mm⁻¹
κ y
−4.30019e-4 mm⁻¹
κ xy
0.00289092 mm⁻¹

ABD stiffness A N/mm · B N · D N·mm

εxεyγxyκxκyκxy
Nx39,38027,2802.728e-129.095e-139.095e-13−1,946
Ny27,28039,3801.819e-129.095e-131.364e-12−1,946
Nxy2.728e-121.819e-1230,980−1,946−1,9469.095e-13
Mx9.095e-139.095e-13−1,9462,3151,6041,090
My9.095e-131.364e-12−1,9461,6042,3151,090
Mxy−1,946−1,9469.095e-131,0901,0901,822

Model and assumptions

A = ΣQ̄ Δz · B = ½ΣQ̄ Δ(z²) · D = ⅓ΣQ̄ Δ(z³) · [N; M] = [A B; B D][ε⁰; κ].

Enter blocks from the bottom face (negative z) to the top face (positive z). Ply count multiplies the thickness of a single ply. The composition is weighted by thickness and “other” contains angles outside 0°, ±45° and 90°.

The bank uses one material and one density for the full stack. Membrane constants come from the upper-left compliance block of the inverted ABD matrix at M = 0. The flexural modulus uses the lower-right compliance block at N = 0.

The coupling flag compares |Bᵢⱼ|/√(AᵢᵢDⱼⱼ) with numerical roundoff. Mirrored layups have B = 0 by symmetry. An unbalanced laminate can still have A₁₆ or A₂₆ even with zero B.

Scope. Thin, perfectly bonded, linear elastic plies. Inputs are purely mechanical resultants, with no transverse shear, thermal load or interlaminar stress recovery.

See calculation methods and references