CompositePlyLab / SI
Balanced angle-ply shell strip
Build a ply stack and solve its extensional, coupling and bending stiffness, in-plane strains and curvature.
- Thickness
- 0.84 mm
- Membrane Ex
- 23.982 GPa
- Bending Ex,f
- 21.96 GPa
- Areal mass
- 1,327.2 g/m²
Extension–bending coupled · Coupling assessed relative to membrane and bending stiffness
Inputs
| Axial modulus E₁ | 142 GPa |
|---|---|
| Transverse modulus E₂ | 10.3 GPa |
| Shear modulus G₁₂ | 7.2 GPa |
| Major Poisson ratio ν₁₂ | 0.27 |
| Ply density | 1.58 g/cm³ |
| Normal load Nx | 0 N/mm |
| Normal load Ny | 0 N/mm |
| Shear load Nxy | 25 N/mm |
| Bending moment Mx | 0 N |
| Bending moment My | 0 N |
| Twisting moment Mxy | 4 N |
Ply blocks · bottom to top
| Angle | Count | Ply thickness |
|---|---|---|
| 45° | 2 | 0.14 mm |
| −45° | 3 | 0.14 mm |
| 45° | 1 | 0.14 mm |
Results
Engineering constants
- Membrane Ey
- 23.9819 GPa
- Membrane Gxy
- 33.3121 GPa
- Membrane νxy
- 0.665408
- Bending Ey,f
- 21.9604 GPa
- Ply count
- 6
- max |Bᵢⱼ|
- 1,946.28 N
Mid-plane response
- ε⁰ x
- 84.4134 µε
- ε⁰ y
- 84.4134 µε
- ε⁰ xy
- 752.971 µε
- κ x
- −4.30019e-4 mm⁻¹
- κ y
- −4.30019e-4 mm⁻¹
- κ xy
- 0.00289092 mm⁻¹
ABD stiffness A N/mm · B N · D N·mm
| εx | εy | γxy | κx | κy | κxy | |
|---|---|---|---|---|---|---|
| Nx | 39,380 | 27,280 | 2.728e-12 | 9.095e-13 | 9.095e-13 | −1,946 |
| Ny | 27,280 | 39,380 | 1.819e-12 | 9.095e-13 | 1.364e-12 | −1,946 |
| Nxy | 2.728e-12 | 1.819e-12 | 30,980 | −1,946 | −1,946 | 9.095e-13 |
| Mx | 9.095e-13 | 9.095e-13 | −1,946 | 2,315 | 1,604 | 1,090 |
| My | 9.095e-13 | 1.364e-12 | −1,946 | 1,604 | 2,315 | 1,090 |
| Mxy | −1,946 | −1,946 | 9.095e-13 | 1,090 | 1,090 | 1,822 |