Worked example

Aramid low-CTE skin

Estimate why a lightweight aramid skin can shrink along the fibers while expanding across them during heating.

Compare both CTE outputs, then reduce fiber volume to increase the matrix contribution to axial expansion.

View live results

Inputs

Fiber and cell
%
%
Fiber properties
GPa
GPa
GPa
µm/m·K⁻¹
µm/m·K⁻¹
g/cm³
Matrix properties
GPa
GPa
µm/m·K⁻¹
g/cm³

Live results

SI
Axial E₁
71.816 GPa
Transverse E₂
4.4115 GPa
Shear G₁₂
1.7347 GPa
Density
1.344 g/cm³
Fiber–matrix unit cell
Fiber and matrix unit cell with axial and transverse modulus bars HEX ARRAYVf 63%E₁71.8E₂4.41GPa
  • Axial stiffness
  • Transverse stiffness
  • Matrix phase
Fiber volume63%
0%100% of unit cell

Constituent balance

Fiber volume
63 %
Fiber weight
67.5 %
Matrix volume
36.4 %
Void volume
0.6 %

Poisson ratio and expansion

Major ν₁₂
0.35
Minor ν₂₁
0.0214996
Axial CTE α₁
−1.19978 µm/m·K⁻¹
Transverse CTE α₂
64.5164 µm/m·K⁻¹

Model and assumptions

E₁ = E₁fVf + EmVm · E₂ and G₁₂ use Halpin–Tsai · α₁ and α₂ use Schapery’s axial and transverse estimates.

Axial stiffness and density use whole-volume fractions. Transverse and shear stiffness use Halpin–Tsai with the fiber fraction of the solid, then multiply by the solid fraction as a simple porosity knockdown.

The major Poisson ratio and the transverse thermal expansion model use solid-phase fractions. Axial stiffness weights the axial phase expansions. Weight fractions exclude void mass.

Choose ξ separately for transverse and shear geometry. The square and hexagonal options change the schematic. Above circular packing, the drawing clips the fiber at contact and the volume readout still shows the entered fraction.

Scope. Aligned continuous fibers, bonded phases and small strains. Porosity shape, fiber waviness and interface effects need a separate model or measured coupon data.

See calculation methods and references