Worked example

Autoclaved carbon tape

Estimate the directional elastic constants of a dense carbon–epoxy tape after autoclave consolidation.

Hold the constituent properties fixed and compare the axial result with the transverse one. The axial mixture carries more of the fiber stiffness.

View live results

Inputs

Fiber and cell
%
%
Fiber properties
GPa
GPa
GPa
µm/m·K⁻¹
µm/m·K⁻¹
g/cm³
Matrix properties
GPa
GPa
µm/m·K⁻¹
g/cm³

Live results

SI
Axial E₁
142.76 GPa
Transverse E₂
8.4144 GPa
Shear G₁₂
4.5408 GPa
Density
1.5642 g/cm³
Fiber–matrix unit cell
Fiber and matrix unit cell with axial and transverse modulus bars HEX ARRAYVf 61.5%E₁143E₂8.41GPa
  • Axial stiffness
  • Transverse stiffness
  • Matrix phase
Fiber volume61.5%
0%100% of unit cell

Constituent balance

Fiber volume
61.5 %
Fiber weight
70.771 %
Matrix volume
38.1 %
Void volume
0.4 %

Poisson ratio and expansion

Major ν₁₂
0.25738
Minor ν₂₁
0.0151696
Axial CTE α₁
−0.0880839 µm/m·K⁻¹
Transverse CTE α₂
33.2912 µm/m·K⁻¹

Model and assumptions

E₁ = E₁fVf + EmVm · E₂ and G₁₂ use Halpin–Tsai · α₁ and α₂ use Schapery’s axial and transverse estimates.

Axial stiffness and density use whole-volume fractions. Transverse and shear stiffness use Halpin–Tsai with the fiber fraction of the solid, then multiply by the solid fraction as a simple porosity knockdown.

The major Poisson ratio and the transverse thermal expansion model use solid-phase fractions. Axial stiffness weights the axial phase expansions. Weight fractions exclude void mass.

Choose ξ separately for transverse and shear geometry. The square and hexagonal options change the schematic. Above circular packing, the drawing clips the fiber at contact and the volume readout still shows the entered fraction.

Scope. Aligned continuous fibers, bonded phases and small strains. Porosity shape, fiber waviness and interface effects need a separate model or measured coupon data.

See calculation methods and references