Worked example

Aramid protective shell

Scale a small aramid shell batch using a 100:40 resin system and a high line-loss allowance.

The resin and hardener outputs use mass rather than liquid volume, in the supplied mix ratio.

View live results

Inputs

Layup
g/m²
m²
%
g/cm³
Resin system
g/cm³
%

Live results

SI
Cured stack
1.3889 mm
Mixed batch
417.09 g
Resin mass
297.92 g
Hardener mass
119.17 g
Cured stack and batch mass
Cured layup thickness and dry fiber, resin and hardener mass budget 6 plies1.39 mmFiber428Resin298Hardener119g
  • Dry fiber
  • Resin
  • Hardener
Fiber weight share of cured part56.798%
0%100% of cured mass

Layup and batch balance

Dry fiber mass
428.4 g
In-part matrix mass
325.85 g
Additional mix for waste
91.238 g
Cured ply thickness
0.231481 mm
Cured areal weight
1,795.83 g/m²
Fiber volume fraction
51 %
Fiber weight fraction
56.7981 %

Model and assumptions

Mf = FAW·A·N · tply = FAW/(1000ρfVf) in mm · Mbatch = Mmatrix(1 + waste).

Use dry fiber areal weight for a single ply and the actual developed part area. The target fiber fraction is a cured-part value. Mixed matrix mass uses the combined resin-system density.

Waste is an additional percentage of the mixed matrix mass needed in the part. The batch split uses weight parts and applies the same ratio to resin retained in the part and waste.

Cured ply thickness follows fiber volume conservation. Press pressure, resin bleed, cure shrinkage and voids affect practical thickness.

Scope. Uniform ply coverage, no void volume and mass-based resin manufacturer ratios. Add process waste from your own feedline, peel ply or bleeder records.

See calculation methods and references