Worked example
Danger flag for a 25° sling angle
A constrained headroom sketch illustrates a 25° horizontal angle on a 4,800 lbf load. The estimate flags both the angle and the entered leg rating.
Estimate
Minimum static WLL per leg
- Danger · a sling angle is below 30° from horizontal. Stop and obtain qualified review.
- Entered WLL is below the calculated static tension.
- Have a qualified person confirm the load, center of gravity, hitch, assembly ratings and dynamic effects before lifting.
- Static tension per working leg
- 5,678.88 lbf
- Hook rise above pickups
- 4.226 ft
- Lowest horizontal angle
- 25 °
- Angle multiplier
- 2.366 ×
- Modeled working legs
- 2
- Entered WLL used
- 113.6 %
- Symmetrical pickup span
- 18.126 ft
Download
Working this example
Starting estimate 5,678.88 lbfMinimum static WLL per leg
Treat the starting scenario as a rejected configuration. A qualified person must evaluate any changes to the lift plan.
Questions & answers
Why does the 25° example flag a 5,000 lbf leg rating?
The 2,400 lbf vertical share divided by sin 25° is about 5,679 lbf. This exceeds the entered rating.
Will entering a stronger sling clear the 25° angle danger flag?
The angle flag remains below 30° even if the static tension is within the entered component rating.