A constrained headroom sketch illustrates a 25° horizontal angle on a 4,800 lbf load. The estimate flags both the angle and the entered leg rating.

Inputs

Measurement system
lbf
Include everything supported below the hook.
°
ft
Measured between the bearing points.
lbf
Enter the governing component rating for the intended use.
SLING FORCE TRIANGLEHorizontal sling angles, projected headroom and the governing static leg tension. SLING FORCE TRIANGLE Pickup elevation25°25°Headroom 4.23 ftLoad 4,800 lbfPeak leg 5,678.88 lbf

Estimate

Minimum static WLL per leg
5,678.88 lbf
  • Danger · a sling angle is below 30° from horizontal. Stop and obtain qualified review.
  • Entered WLL is below the calculated static tension.
  • Have a qualified person confirm the load, center of gravity, hitch, assembly ratings and dynamic effects before lifting.
Static tension per working leg
5,678.88 lbf
Hook rise above pickups
4.226 ft
Lowest horizontal angle
25 °
Angle multiplier
2.366 ×
Modeled working legs
2
Entered WLL used
113.6 %
Symmetrical pickup span
18.126 ft
Download

Working this example

Starting estimate 5,678.88 lbfMinimum static WLL per leg

Treat the starting scenario as a rejected configuration. A qualified person must evaluate any changes to the lift plan.

See the calculator formulas and assumptions

Questions & answers

Why does the 25° example flag a 5,000 lbf leg rating?

The 2,400 lbf vertical share divided by sin 25° is about 5,679 lbf. This exceeds the entered rating.

Will entering a stronger sling clear the 25° angle danger flag?

The angle flag remains below 30° even if the static tension is within the entered component rating.