Rigging Sling Angle, Leg Tension & WLL Calculator

Compare sling angles, static leg tensions, headroom and working load limits for one- to four-leg configurations.

Inputs

Measurement system
lbf
Include everything supported below the hook.
°
ft
Measured between the bearing points.
lbf
Enter the governing component rating for the intended use.
SLING FORCE TRIANGLEHorizontal sling angles, projected headroom and the governing static leg tension. SLING FORCE TRIANGLE Pickup elevation60°60°Headroom 8.66 ftLoad 10,000 lbfPeak leg 5,773.5 lbf

Estimate

Minimum static WLL per leg
5,773.5 lbf
  • Have a qualified person confirm the load, center of gravity, hitch, assembly ratings and dynamic effects before lifting.
Static tension per working leg
5,773.5 lbf
Hook rise above pickups
8.66 ft
Lowest horizontal angle
60 °
Angle multiplier
1.155 ×
Modeled working legs
2
Entered WLL used
88.8 %
Symmetrical pickup span
10 ft
Download

How the estimate works

  1. Use the horizontal angle

    An equal-angle leg carrying one share of the vertical load has tension equal to that share divided by sin θ. The model counts up to three working legs.

  2. Resolve unequal two-leg geometry

    For left angle α and right angle β with level pickups, force balance gives left tension W cos β ÷ sin(α + β) and right tension W cos α ÷ sin(α + β). The hook must align above the combined center of gravity.

  3. Compare static tension with the entered rating

    Headroom is the vertical distance from pickup elevation to the hook geometry. Compare the larger static tension with the applicable per-leg rating and verify the assembly with a qualified person.

References

Questions & answers

Why does a flatter sling angle raise leg tension?

Only the vertical component supports the load. A flatter leg supplies less vertical force per unit of tension, so its total tension rises.

How does the calculator count a fourth leg?

The equal-angle static model assumes three working legs for a four-leg assembly. Real distribution depends on the rigging, pickup elevations, stiffness and center of gravity.

How should I interpret a sling angle below 30 degrees?

Treat the result as a danger flag. Stop and have a qualified person or the sling manufacturer review the actual configuration.