Gantry notch close to crossover
A gantry resonance sits close enough to crossover to affect phase reserve.
Model inputs
- Architecture
- Biquad notch
- Sample rate
- 1800 Hz
- Design center
- 92 Hz
- Zero damping ζz
- 0.025
- Pole damping ζp
- 0.31
- Loop crossover
- 71 Hz
Model inputs
Realized compensator frequency response
Check phase reserveCheck the model inputs
- Notch depth
- −21.868dB
- Phase penalty
- −44.03°
- Digital BW
- 55.524Hz
- Notch center
- 92Hz
Calculated results
- Notch depth
- −21.868dB
- Analog −3 dB bandwidth
- 56.668Hz
- Digital lower edge
- 68.196Hz
- Digital upper edge
- 123.72Hz
- Digital −3 dB bandwidth
- 55.524Hz
- Analog crossover phase
- −44.345°
- Digital crossover phase
- −44.03°
- b0
- 0.91805813446229
- b1
- -1.728605862776566
- b2
- 0.9036823685784813
- a1
- -1.728605862776566
- a2
- 0.8217405030407716
- Bandwidth uses the half-power threshold (−3.0103 dB). Verify the digital phase penalty against full-loop stability margins.
Model and interpretation
Full methodologyPlace the peak phase change
The unwarped lead prototype places its zero at ωm/√α and pole at ωm√α. Lag interchanges the pole and zero and reverses the phase sign. The high-frequency to DC gain ratios are α for lead and 1/α for lag.
Check notch width and crossover lag
The notch zero damping is strictly smaller than its pole damping. The half-power edges exist only for ζz/ζp ≤ 1/√2. A wider notch can reduce phase reserve far below the resonance. Compare the realized penalty at the intended loop crossover.
Transfer the digital coefficients
The bilinear transform is prewarped at the design center. Coefficients use the same a0 = 1 and negative-feedback convention as the IIR calculator. Recheck pole stability and quantization in the target realization.