ControlLoopLab
Home ADC & aliasingWorked example

Reference tone exactly at Nyquist

A bench generator is set to exactly one-half of the acquisition rate.

Model inputs

Converter & noise
bits
V
dB
Sampling & antialiasing
Hz
Hz
Hz

Spectrum folding & anti-alias roll-off

At Nyquist boundary
ENOB
12.664bits
1 LSB
250µV
Folded input
24000Hz
Image reject
10.409dB
Nyquist-zone folding and analog rejectionNyquist-zone foldingHz024000480007200096000080001600024000Input frequency (Hz)Analog filter roll-offdB024000480007200096000−100−66.7−33.30Input frequency (Hz)Zone 2 inputFold 24000 Hz
ENOB = (SINAD − 1.76)/6.02 · falias = min(fsig mod fs, fs − fsig mod fs)

Calculated results

Ideal quantizer SNR
86.04dB
Code width
250µV
SINAD or noise-limited SNR
78dB
Effective bits
12.664bits
Equivalent RMS noise
182.31µV
6.6σ peak-to-peak noise
1203.3µV
Noise-free bits (estimate)
11.733bits
Nyquist boundary
24000Hz
Nyquist zone
2
Folded frequency
24000Hz
Image |fs − fsig|
24000Hz
Butterworth image rejection
10.409dB
Image leakage, full-scale peak
2471.2LSB
Filter attenuation at input
−10.409dB
  • SINAD yields equivalent RMS noise plus distortion. Noise-free code width requires an independent DC noise measurement.
  • Image leakage assumes a full-scale sine peak and an ideal analog Butterworth response.

Model and interpretation

Full methodology

Distinguish code width, ENOB and quiet codes

Code width is the full input span divided by 2ᴺ. The SINAD conversion assumes a full-scale sine. Noise-free bits use a 6.6σ peak-to-peak estimate. For genuine quiet-code resolution, use a measured DC noise distribution.

Measure SFDR separately

Enter the fundamental and largest spur levels from the same FFT in dBFS. Their difference is SFDR in dBc. SINAD combines noise and distortion, so it cannot provide SFDR.

Fold at half the sample rate

A spectral line folds into 0 to fs/2. Zones start at multiples of fs/2. A line exactly at Nyquist is a boundary case with phase-dependent sampled amplitude. An apparent baseband line does not establish its original zone.

Screen the first reflected image

The modeled image is |fs − fsig|. Rejection uses an analog Butterworth prototype; leakage in LSB is relative to a full-scale sinusoidal peak. Evaluate all actual blockers and converter front-end bandwidth for a real noise budget.