DistillColumnLab
Menu

Worked example · Reaction engineering

Arrhenius temperature correction

Compare ideal reactor volumes, space time and equal-tank conversion for zero-, first- or second-order kinetics.

A reaction characterized at 25 °C operates at 55 °C with an activation energy of 38 kJ/mol.

CSTR volume
6.306 m³
PFR volume
3.254 m³
CSTR / PFR
1.938
Cascade X
63.66 %

Levenspiel volume comparison

Live schematic
Levenspiel plot of PFR area under the rate curve and the CSTR rectangle00.160.310.470.630.7802.557.610Fₐ₀ / (−rₐ) · m³CONVERSION XPFR areaCSTR rectangleCascade check
PFR-sized cascade falls short

The conversion check holds total cascade volume at the PFR volume. Use the separate cascade size to meet the target.

PFR-sized cascade conversion vs target63.7 %
Near target 69.7 % Target 70 %

Worked solution

  1. Evaluate the rate at temperature

    The Arrhenius correction gives k = 3.33 h⁻¹. At X = 70 %, CA = 0.375 kmol/m³.

  2. Compare the Levenspiel areas

    The outlet-rate rectangle gives 6.306 m³. Integrating through the concentration change gives 3.254 m³. The single-tank penalty is 1.938 times.

  3. Check the cascade

    3 equal tanks at PFR total volume reach 63.66 %. At the target, the cascade requires 4.004 m³ total.

Calculate the operating rate constant from absolute temperatures before integrating the volume. The derivation uses SI units.

Calculation details
Operating rate constant3.33 h⁻¹
Total cascade volume at target4.004 m³
Volume per equal tank1.335 m³
CSTR space time0.7007 h
PFR space time0.3616 h
Cascade space time at target0.4449 h
Outlet concentration CA0.375 kmol/m³
PFR-sized cascade shortfall6.34 pp

Calculation inputs

Live updates

Kinetics
h⁻¹
°C
°C
kJ/mol
0 disables temperature correction
Feed and design target
m³/h
kmol/m³
%
Back to results

Equations and assumptions

Power-law kinetics
−rA = k · CA^n
Temperature adjustment
k = kref exp[(Ea/R)(1/Tref − 1/T)]
Single CSTR
VCSTR = FA₀X / [k CA₀^n (1 − X)^n]
Plug flow
VPFR = ∫₀ˣ FA₀ / (−rA) dX

The ideal model is steady state, isothermal and constant density. It assumes one irreversible power-law reaction and no change in volumetric flow. Enter a rate constant with units for the selected order.

The cascade check divides the PFR volume among equal CSTRs. A separate cascade sizing step computes the volume needed at the target. For second order each tank solves Ci + kτtank Ci² = Ci−1 using a cancellation-safe positive root.

Method references