Worked example · Gas–solid separation
High-velocity cyclone screen
Estimate d₅₀, target-particle capture, pressure drop and inlet velocity for a tangential gas cyclone.
A 550 mm Stairmand cyclone is loaded with 4,200 actual m³/h of gas.
- Cut size d₅₀
- 2.453 µm
- Grade capture
- 85.68 %
- Inlet speed
- 38.57 m/s
- Pressure drop
- 5.95 kPa
Cyclone vortex and grade-efficiency curve
Live schematicCheck erosion, pressure loss and dust re-entrainment above the 20 m/s screen.
Calculation inputs
- Inlet gas flow Qg
- 4,200 Am³/h
- Gas density ρg
- 1.25 kg/m³
- Gas viscosity μ
- 0.0184 mPa·s
- Particle density ρp
- 2,500 kg/m³
- Target particle diameter
- 6 µm
- Effective turns Ne
- 5
- Geometry preset
- Stairmand high efficiency
- Barrel diameter Dc
- 0.55 m
- Inlet height a/D
- 0.5
- Inlet width b/D
- 0.2
- Gas outlet De/D
- 0.5
- Finder immersion S/D
- 0.5
- Barrel height h/D
- 1.5
- Overall height H/D
- 4
- Dust outlet B/D
- 0.375
Worked solution
- Find the inlet velocity
At an inlet area of 0.03025 m², the actual gas flow gives vi = 38.57 m/s.
- Calculate the grade point
Lapple gives a 50% cut of 2.453 µm. At 6 µm, the fractional capture is 85.68 %.
- Evaluate static pressure loss
The geometry gives 6.4 velocity heads. Multiplying by ½ρg vi² yields 5.95 kPa.
The smaller cut point accompanies a higher pressure loss and re-entrainment screening flag. The derivation uses SI units.
| Shepherd–Lapple velocity heads NH | 6.4 |
|---|---|
| Tangential inlet area | 0.03025 m² |
| Inlet height | 275 mm |
| Inlet width | 110 mm |
| Vortex finder bore | 275 mm |
| Overall body height | 2.2 m |
Calculation inputs
Live updates
Equations and assumptions
- Inlet velocity
- vi = Qg/(a · b)
- Cut diameter
- d₅₀ = √[9 μ b / (2π Ne vi (ρp − ρg))]
- Fractional capture
- η = 1/[1 + (d₅₀/dp)²]
- Pressure drop
- ΔP = 0.5 ρg vi² NH · NH = 16 a b/De²
Preset dimensions are published standard proportions. The pressure-drop coefficient is the Shepherd–Lapple estimate for a standard tangential inlet. Effective turns are an explicit Lapple model input.
The grade curve predicts collection at one particle diameter. Overall mass efficiency additionally requires a particle-size distribution. The meter marks a 20 m/s screening ceiling, with an additional high-velocity flag above 25 m/s.