A Swift high-throughput cyclone handles 6,200 actual m³/h in a 680 mm shell.

Cut size d₅₀
6.476 µm
Grade capture
84.29 %
Inlet speed
13.3 m/s
Pressure drop
0.8314 kPa

Cyclone vortex and grade-efficiency curve

Live schematic
Tangential cyclone flow and Lapple grade-efficiency curve08.216.424.60%50%100%TANGENTIAL INLET13.3 m/sGRADE EFFICIENCYPARTICLE SIZE µmOuter vortexGrade curveTarget particle
Within inlet velocity band

The inlet velocity falls within the 10–20 m/s screening band.

Tangential inlet velocity13.3 m/s
Review marker 20 m/s Screen limit 25 m/s

Worked solution

  1. Find the inlet velocity

    At an inlet area of 0.1295 m², the actual gas flow gives vi = 13.3 m/s.

  2. Calculate the grade point

    Lapple gives a 50% cut of 6.476 µm. At 15 µm, the fractional capture is 84.29 %.

  3. Evaluate static pressure loss

    The geometry gives 7.964 velocity heads. Multiplying by ½ρg vi² yields 0.8314 kPa.

Use the Swift inlet and vortex finder proportions to calculate velocity heads. The derivation uses SI units.

Calculation details
Shepherd–Lapple velocity heads NH7.964
Tangential inlet area0.1295 m²
Inlet height544 mm
Inlet width238 mm
Vortex finder bore510 mm
Overall body height2.516 m

Calculation inputs

Live updates

Gas and solids
Am³/h
kg/m³
mPa·s
kg/m³
µm
Cyclone geometry

Editing a proportion switches the preset to Custom.

m
Back to results

Equations and assumptions

Inlet velocity
vi = Qg/(a · b)
Cut diameter
d₅₀ = √[9 μ b / (2π Ne vi (ρp − ρg))]
Fractional capture
η = 1/[1 + (d₅₀/dp)²]
Pressure drop
ΔP = 0.5 ρg vi² NH · NH = 16 a b/De²

Preset dimensions are published standard proportions. The pressure-drop coefficient is the Shepherd–Lapple estimate for a standard tangential inlet. Effective turns are an explicit Lapple model input.

The grade curve predicts collection at one particle diameter. Overall mass efficiency additionally requires a particle-size distribution. The meter marks a 20 m/s screening ceiling, with an additional high-velocity flag above 25 m/s.