DistillColumnLab
Menu

Worked example · Gas–solid separation

High-velocity cyclone screen

Estimate d₅₀, target-particle capture, pressure drop and inlet velocity for a tangential gas cyclone.

A 550 mm Stairmand cyclone is loaded with 4,200 actual m³/h of gas.

Cut size d₅₀
2.453 µm
Grade capture
85.68 %
Inlet speed
38.57 m/s
Pressure drop
5.95 kPa

Cyclone vortex and grade-efficiency curve

Live schematic
Tangential cyclone flow and Lapple grade-efficiency curve03.116.219.320%50%100%TANGENTIAL INLET38.6 m/sGRADE EFFICIENCYPARTICLE SIZE µmOuter vortexGrade curveTarget particle
High inlet velocity

Check erosion, pressure loss and dust re-entrainment above the 20 m/s screen.

Tangential inlet velocity38.6 m/s
Review marker 20 m/s Screen limit 25 m/s

Worked solution

  1. Find the inlet velocity

    At an inlet area of 0.03025 m², the actual gas flow gives vi = 38.57 m/s.

  2. Calculate the grade point

    Lapple gives a 50% cut of 2.453 µm. At 6 µm, the fractional capture is 85.68 %.

  3. Evaluate static pressure loss

    The geometry gives 6.4 velocity heads. Multiplying by ½ρg vi² yields 5.95 kPa.

The smaller cut point accompanies a higher pressure loss and re-entrainment screening flag. The derivation uses SI units.

Calculation details
Shepherd–Lapple velocity heads NH6.4
Tangential inlet area0.03025 m²
Inlet height275 mm
Inlet width110 mm
Vortex finder bore275 mm
Overall body height2.2 m

Calculation inputs

Live updates

Gas and solids
Am³/h
kg/m³
mPa·s
kg/m³
µm
Cyclone geometry

Editing a proportion switches the preset to Custom.

m
Back to results

Equations and assumptions

Inlet velocity
vi = Qg/(a · b)
Cut diameter
d₅₀ = √[9 μ b / (2π Ne vi (ρp − ρg))]
Fractional capture
η = 1/[1 + (d₅₀/dp)²]
Pressure drop
ΔP = 0.5 ρg vi² NH · NH = 16 a b/De²

Preset dimensions are published standard proportions. The pressure-drop coefficient is the Shepherd–Lapple estimate for a standard tangential inlet. Effective turns are an explicit Lapple model input.

The grade curve predicts collection at one particle diameter. Overall mass efficiency additionally requires a particle-size distribution. The meter marks a 20 m/s screening ceiling, with an additional high-velocity flag above 25 m/s.

Method references