Worked example · Distillation
Feed tray for a lean light key
Estimate minimum reflux, theoretical stages, actual trays and feed location for a binary split.
A feed with 24 mol% light key is split into an 89 mol% distillate and 2.5 mol% bottoms.
- Min stages
- 8.016
- Min reflux
- 3.249
- Theory stages
- 12.36
- Actual trays
- 15
McCabe–Thiele construction
Live schematicInternal liquid and vapor flows are positive. The staircase is an independent equilibrium-stage construction.
Calculation inputs
- Relative volatility α
- 2.05
- Feed light key xF
- 0.24
- Distillate light key xD
- 0.89
- Bottoms light key xB
- 0.025
- Feed quality q
- 1
- Reflux multiplier R/Rmin
- 1.8
- Overall stage efficiency
- 78 %
Worked solution
- Get the total-reflux stage floor
Use α = 2.05, xD = 0.89 and xB = 0.025 in the Fenske log-odds ratio. Nmin = 8.016.
- Find the reflux floor
Bracket the feed-quality root between 1 and α. At θ = 1.63738, the product equation gives Rmin = 3.249. Multiply by 1.8 to get R = 5.848.
- Size trays and allocate the sections
Gilliland gives 12.36 stages. Remove the equilibrium reboiler and apply Eₒ = 78 % to get 15 trays. Kirkbride gives NR/NS = 0.865 and feed tray 7 from the top.
The unequal product split enters Kirkbride through B/D, so tray location follows composition and flow. The derivation uses SI units.
| Underwood root θ | 1.63738 |
|---|---|
| Operating reflux R | 5.848 |
| Distillate recovery D/F | 24.86 % |
| Bottoms split B/F | 75.14 % |
| Kirkbride stage ratio NR/NS | 0.865 |
| Feed tray from top | 7 |
| Condenser vapor V/D | 6.848 |
| Reboiler vapor V̄/B | 2.265 |
| Rectifying vapor V/F | 1.702 |
| Stripping vapor V̄/F | 1.702 |
Calculation inputs
Live updates
Equations and assumptions
- Minimum stages
- Nmin = [logit(xD) − logit(xB)] / ln(α)
- Minimum reflux
- Σ αᵢ zᵢ / (αᵢ − θ) = 1 − q
- Reflux and stages
- X = (R − Rmin)/(R + 1) · Y = (N − Nmin)/(N + 1)
- Feed-stage split
- NR/NS = [(B/D)((1−xF)/xF)(xB/(1−xD))²]^0.206
The model uses constant relative volatility, constant molar overflow, a total condenser and one equilibrium reboiler. The theoretical total includes the reboiler. The actual tray count applies efficiency after subtracting that reboiler.
Gilliland uses the Molokanov exponential fit. Kirkbride estimates the section split and the feed tray is rounded from the top of the column. The McCabe–Thiele staircase uses the two material-balance operating lines at the entered reflux and may give a different stage count.
q below 0 represents superheated vapor and q above 1 represents subcooled liquid. The reflux multiplier requires positive minimum reflux and positive internal stripping flows.