Saturated-vapor distillation feed

Estimate minimum reflux, theoretical stages, actual trays and feed location for a binary split.

A vaporized binary feed enters at its dew point. Size the stages at 1.65 times minimum reflux.

Min stages
6.633
Min reflux
2.763
Theory stages
11
Actual trays
16

McCabe–Thiele construction

Live schematic
McCabe–Thiele equilibrium and operating lines00.20.40.60.8100.20.40.60.81VAPOR LIGHT KEY yLIQUID LIGHT KEY xFEED QUALITYq 0OPERATING REFLUXR 4.559FEED TRAY9 from topFull staircaseEquilibriumOperating linesStages
Above minimum reflux

Internal liquid and vapor flows are positive. The staircase is an independent equilibrium-stage construction.

Reflux demand ÷ operating reflux60.6 %
Review marker 87 % Screen limit 100 %

Worked solution

  1. Get the total-reflux stage floor

    Use α = 2.4, xD = 0.94 and xB = 0.045 in the Fenske log-odds ratio. Nmin = 6.633.

  2. Find the reflux floor

    Bracket the feed-quality root between 1 and α. At θ = 1.812, the product equation gives Rmin = 2.763. Multiply by 1.65 to get R = 4.559.

  3. Size trays and allocate the sections

    Gilliland gives 11 stages. Remove the equilibrium reboiler and apply Eₒ = 65 % to get 16 trays. Kirkbride gives NR/NS = 1.015 and feed tray 9 from the top.

The q-line is horizontal. Check how vapor entering with the feed reduces reboiler boil-up. The derivation uses SI units.

Calculation details
Underwood root θ1.812
Operating reflux R4.559
Distillate recovery D/F41.9 %
Bottoms split B/F58.1 %
Kirkbride stage ratio NR/NS1.015
Feed tray from top9
Condenser vapor V/D5.559
Reboiler vapor V̄/B2.288
Rectifying vapor V/F2.329
Stripping vapor V̄/F1.329

Calculation inputs

Live updates

Equilibrium and split

Enter light-key mole fractions as decimals.

Light key to heavy key
Operating basis
0 vapor · 1 liquid
%
Back to results

Equations and assumptions

Minimum stages
Nmin = [logit(xD) − logit(xB)] / ln(α)
Minimum reflux
Σ αᵢ zᵢ / (αᵢ − θ) = 1 − q
Reflux and stages
X = (R − Rmin)/(R + 1) · Y = (N − Nmin)/(N + 1)
Feed-stage split
NR/NS = [(B/D)((1−xF)/xF)(xB/(1−xD))²]^0.206

The model uses constant relative volatility, constant molar overflow, a total condenser and one equilibrium reboiler. The theoretical total includes the reboiler. The actual tray count applies efficiency after subtracting that reboiler.

Gilliland uses the Molokanov exponential fit. Kirkbride estimates the section split and the feed tray is rounded from the top of the column. The McCabe–Thiele staircase uses the two material-balance operating lines at the entered reflux and may give a different stage count.

q below 0 represents superheated vapor and q above 1 represents subcooled liquid. The reflux multiplier requires positive minimum reflux and positive internal stripping flows.

Method references